Siemens TFT User Manual
Page 116
Explosion-Proof Housings and Mounts
Explosion-Proof Pan/Tilt Units
6-6
© Siemens Building Technologies Group
Type
Order No.
FP50B..
Phoenix Explosion-Proof Heavy Duty Aluminium Pan-Tilt Units
ATEX Certified for IIB Applications
The "Phoenix Explosion-Proof" equipment is ATEX-certified to be used
in potentially hazardous areas where there is a risk of explosion
because flammable gases‚ vapours‚ mists or dusts may be present. The
unit is designed to prevent explosion by containing any heat‚ sparks‚ or
flames generated. This prevents ignition of potentially explosive atmos-
pheres or materials outside the equipment. The unit is ATEX-certified
for use in IIB gas environments (includes ethylene and propane). The
pan & tilts are fitted with potentiometers‚ and 230‚ 110 and 24 V AC ver-
sions are available.
Please note‚ that Siemens cannot supply ATEX IIB Equipment certifi-
cates unless the Phoenix-CERT option is ordered with each PTZ.
Approval
Certification to European ATEX
Directive 94/9/EC. Ex ii 2 GD (EExd
IIB T6)
Dimensions (W x H x D)
167 x 291 x 471 mm
Colour
Body: Polyester Powdercoat
RAL1021 (Yellow).
Endplates: Clear Anodised.
Cable entry
Internal terminal block‚ 1 off 20 mm
x 1.5 threaded hole for certified
gland.
Pan speed
4.5°/sec
Torque 45 Nm
Backlash ±0.15° (max.)
Tilt speed
e.5°/sec
Torque 45 Nm
Backlash ±0.15° (max.)
Rotation
Pan 252° (max.)
Tilt ±172°
Finish
Aluminium
Load rating
40 kg
Protection rating
IP67 BS EN 60 529
Weight
19.0 kg
FP50B..
FP50B
Phoenix Explosion-Proof ATEX IIB preset Pan-Tilt 230 V AC
As FP50B.. for technical details‚ but with the following differences:
Power requirements
230 V AC‚ 50/60 Hz
Power consumption
30 VA
S24245-C4060-A1
FP50B/L
Phoenix Explosion-Proof ATEX IIB preset Pan-Tilt 24 V AC
As FP50B.. for technical details‚ but with the following differences:
Power requirements
24 V AC‚ 50/60 Hz
Power consumption
31 VA
S24245-C4060-A3
FP50B/U
Phoenix Explosion-Proof ATEX IIB preset Pan-Tilt 110 V AC
As FP50B.. for technical details‚ but with the following differences:
Power requirements
110 V AC‚ 50/60 Hz
Power consumption
33 VA
S24245-C4060-A2