Siemens TFT User Manual
Page 102
Pan/Tilt and Telemetry Equipment
Pan/Tilt Telemetry Receivers / Drivers
4-12
© Siemens Building Technologies Group
Type
Order No.
RX217D-PCBCD
17 Function Telemetry Receiver Board
Offers full variable-speed control and faster preset positioning capabil-
ity‚ for DC systems with pan-tilt and zoom lenses. Also gives iris control
and auxiliary functions. Compatible with all telemetry controllers
(Molynx protocol). Shortest route to pre-set position. For ease of
control‚ pan speed slows down for zoom. PCB only.
Power requirements
230 D 240 V AC‚ 50/60 Hz
Power consumption
20 W
P/T head control voltage
24 V DC
Address codes
256
Baud rate
9600 bps
Control functions
17
Compatible with
Controllers / matrix switchers with
Molynx protocol
Operating temperature range
-20° C to +40° C
Telemetry formats
C Type (Coax) or
D Type (RS485‚ Molynx protocol)
MTBF
At 25° C 30‚000 h
Dimensions (W x H x D)
210 x 135 x 280 mm
Weight
PCB: 0.50 kg
Box: 1.75 kg
BPZ:80-208
RX217-PCBCD
17 Function Telemetry Receiver Board
RX217 board only‚ for use in applications where a customer-specific
enclosure or other installation is to be used. Offers preset positioning
capability‚ for fixed-speed AC systems with pan‚ tilt and zoom. Also
gives iris control and auxiliary functions. Compatible with all RX telem-
etry controllers. Can accept C or D telemetry. Supports up to 99 pre-
sets. Automatic home positioning.
Power requirements
230 D 240 V AC‚ 50/60 Hz
P/T head control voltage
230 V AC
Address codes
256
Baud rate
9600 bps
Control functions
17
Compatible with
Controllers / matrix switchers with
Molynx protocol
Operating temperature range
-20° C to +40° C
Telemetry formats
C Type (Coax) or
D Type (RS485‚ Molynx protocol)
MTBF
At 25° C 30‚000 h
Dimensions (W x H x D)
120 x 30 x 195 mm
BPZ:80-209