beautypg.com

Connecting the alarm i/o terminals, Alarm input terminal, Preparations (step 1 connection and installation) – JVC VN-C655U User Manual

Page 18: Input requirements

background image

18

6. Connecting the Alarm I/O Terminals

Connect to the equipment with alarm input terminal using the alarm signal cable.

Input Requirements

• No-voltage relay input or NPN open collector

input

• The polarity of the input detection can be

selected via software.

• Make/Break/Toggle (at least 500 ms)
• Circuit current at low level: 0.6 mA
• Voltage applied at high level: 18 V

7. Alarm Input Terminal

This terminal is for connecting with a sensor, infrared, door or metallic, or a manual
switch.

VN-C655

Sensor

Connection

Example 1

Terminal 1 or 2

OUT

R

DC18V

(Alarm input equivalent circuit)

Grounding
terminal

GND

0.6mA

R

VCC

Sensor

Connection

Example 2

OUT

GND

18V

Relay, switch etc.

• The connector can be released by loosening the

screws on the two sides as shown in the figure.

• Strip the coating of each cable by about 4 mm

before inserting it. After connecting all of the
cables, turn the screws on the side to fasten the
connectors.

Cable Specifications
50 m max.

UL1007, UL1015 or equivalent

AWG #22 to AWG #18 or equivalent

Caution

Due to external noise, the camera may not
work properly even if the length of the cable
is less than 50 m. If this occurs, use a
shielded cable or keep the cable away from
the noise source.

Preparations (Step 1 Connection and Installation)

Cable Connections (continued)

Flat-blade
screwdriver

Cable

4 mm

Flat-blade
screwdriver

VN-C655(reed me)_p2-29

04.9.22, 8:18 PM

18