v1.0 26-Nov-2002 - Initial Release
v1.1 1-Mar-2003
•
Reduced the size of HTML pages by removing spaces and tabs to conserve
memory
•
Changed SetDirect.cgi form method from POST to GET
•
Cancel 5-minute direct access window after successful connection
•
"Cook" Telnet input (strip non-text telnet command codes)
•
Streamlined the Ethernet/Serial PassThru functionality
(Both Serial to Ethernet and Ethernet to Serial)
•
Remove STDIO redirection to Serial Port A
(Use telnet for debugging purposes)
•
Send SMTP debug info to Telnet (if in debug mode)
•
Only reboot when a change of settings require it (i.e. IP Address)
•
Added "Reset Web Xpander" link on Settings page
•
Bypass Telnet login prompts if username and password are empty
•
Internet time sync will not occur earlier than scheduled
•
Internet time sync will set STARGATE clock on the minute (i.e. 0 seconds)
since you can't specify seconds in the STARGATE "set time" function
•
Up to 5 :mailto=xxx supported
•
Corrected handling of PreSet DIM Commands (Extended Code vs non-Ext)
•
Added FTP to add files to XMEM RAM (battery backed)
•
Moved mega_x10.shml into XMEM RAM (battery backed)
•
Added ":factory=" to reset to factory settings
•
Fixed DHCP lease expiration problem
•
Added "checksum" command to telnet debug console to calculate and display
Flash memory checksum
•
Moved "Last Successful Time Sync" to XMEM (saved during reset)
•
Corrected issues with controlling and monitoring 8 Channel Relay Xpanders
•
Moved device label storage to a "file" that can be FTPed into the Web Xpander
v1.2 15-Apr-2003
•
Added web page for custom application interaction
sendcommand.cgi : Sends command to STARGATE and returns results
as plain text via HTTP
sendcommand.cgi?var1=
The choices for var2 are “time” or “str”.