Static convergence adjustment, Dynamic convergence adjustment – JVC AV-14F3 User Manual
Page 30

No.52026
AV-14F3/AV-1435
AV-1435EE/AV-1435TEE
AV-14FMT3/AV-1438
AV-14FMG3/AV-14FMG3B
30
STATIC CONVERGENCE ADJUSTMENT
1. Input a cross hatch signal.
2. Using 4-pole convergence magnets , overlap the red and blue
lines in the center of the screen (Fig.1) and turn them to
magenta (red/blue).
3.
Using 6-pole convergence magnets, overlap the
magenta(red/blue) and green lines in the center of the screen
and turn them to white.
4. Repeat 2 and 3 above, and make best c onvergence.
DYNAMIC CONVERGENCE ADJUSTMENT
1. Move the deflec tion yok e up and down and overlap the lines in
the periphery. (Fig. 2)
2. Move the deflection yoke left to right and overlap the lines in the
periphery. (Fig. 3)
3. Repeat 1 and 2 above, and make best c onvergence.
●
After adjustment, fix the wedge at the original position.
Fasten the retainer screw of the deflection yoke.
Fix the 6 magnets with glue.
(FRONT VIEW )
GREEN
(FRONT VIEW )
BLUE
RED
BLUE
GREEN
RED
RED
GREEN
BLUE
GREEN
RED
BLUE
GREEN
(FRONT VIEW )
BLUE
RED
BLUE
GREEN
RED
RED
GREEN
BLUE
GREEN
RED
BLUE
Fig.3
Fig.2
Fig.1