JVC AV-14F3 User Manual
Page 26

No. 52026
AV-14F3/AV-1435
AV-1435EE/AV-1435TEE
AV-14FMT3/AV-1438
AV-14FMG3/AV-14FMG3B
26
Item
Measuring
instrument
Test point
Ad justment part
Description
7.SECAM
BL ADJUST
[Method of adjustment using measuring instrument]
Ad justment
of SECAM
BL ACK
OFFSET
Remote
control unit
Signal
generator
1. Input a SECAM full field c olour bar signal.
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 7. SECAM BL ADJUST with MENU ▼ /▲ key.
5. Set the initial setting value with the MENU - / + key.
6. Switch the ①key (c olour OFF) and ②key (c olour ON) on the
remote control and make sure that there is no colour on the
blac k and white screen.
7. If the black and white screen is not best with the initial setting
value, make fine adjustment until you get the best black and
white screen.
8. While watching the screen, adjus t the value to be the s ame
colour between ON & OFF by ten key on the remote c ontrol
unit.
9. Press the DISPLAY key twice to return to the normal screen.
KEY ASSIGNMENT OF REMOTE CONTROL UNIT
1
2
3
4
5
6
7
8
9
COLOUR
ON
COLOUR
OFF