JVC AV-14F3 User Manual
Page 25

No. 52026
AV-14F3/AV-1435
AV-1435EE/AV-1435TEE
AV-14FMT3/AV-1438
AV-14FMG3/AV-14FMG3B
25
Item
Measuring
instrument
Test point
Ad justment part
Description
6. TINT
[Method of adjustment without measuring instrument]
NTSC 3.58 TINT
1. Input a NTSC 3.58 full field colour bar signal (75% white).
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 6. TINT with the MENU ▼/▲ key.
5. Set the initial s etting value of NTSC 3.58 with the MENU - / +
key.
6. If you cannot get the best tint with the initial s etting value, make
fine adjustment until you get the best tint.
Ad justment
of TINTⅠ
Ⅰ
Ⅰ
Ⅰ
Signal
generator
Remote
control unit
NTSC 4.43 TINT
When NTSC 3.58 is set, NTSC 4.43 will be automatically set at the
respective values .
6. TINT
[Method of adjustment using measuring instrument]
NTSC 3.58 TINT
1. Input a NTSC 3.58 full field colour bar signal (75% white).
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 6. TINT with the MENU ▼/▲ key.
5. Set the initial s etting value of NTSC 3.58 with the MENU - / +
key.
6. Connect the osc illosc ope between TP-47G/R and TP-E. (#).
7. Adjust NTSC 3.58 TINT to bring the value of
(B)
in the
illustration +9V(W- Cy). (Voltage value between (W) and (Cy))
Ad justment
of TINTⅡ
Ⅱ
Ⅱ
Ⅱ
Signal
generator
Oscillo-
scope
Remote
control unit
TP-47G/R
TP-E (#
#
#
#
)
[CRT
SOCKET
PWB]
NTSC 4.43 TINT
When NTSC 3.58 is set, NTSC 4.43 will be automatically set at the
respective values .
W
Y
Cy
G
Mg
R
B
(B)
0V
(-)
(+)