Installation Instructions

OUZXMAG,0001BF6

–19–18NOV03–1/2

Check Yield Monitoring Functionality

Calibrate Mass-Flow Sensor

1. Turn ignition key to RUN position.

2. Press “SETUP” key to enter SETUP mode.

3. Press key C in “SETUP” to select “GreenStar

Display”.

4. Select your native language and units then press key

G once to go back.

5. Press key A to select “Harvest Mon”.

6. Make sure that “Recording ON/OFF By:” is set on

HEADER” then press key G once to go back.

7. Press key D to select “Yield Calibration”.

8. Press key A to start calibration. Wait until feedroll

height is 10 mm (0.4 in.).

9. Press RUN key.

Check Monitoring Functions

1. Turn ignition key to start harvester engine.

2. Press “INFO” key to enter INFO mode.

3. Press key A in “INFO” to select “Harvest Mon”.

4. Press key F to select “Diagnostics”.

5. Press key B to select “Mass-Flow System”. Engage

main clutch and harvesting unit then check the
following points:

Height right—should be between 0.2 and 0.6 V.

Vref—Should be between 4.8 and 5.1 V.

If any of these points are not OK, contact your John
Deere dealer.

Press key G once to go back.