Installation Instructions

OUCC002,00021CD

–19–18NOV06–4/4

ZX1039600

F

E

F

E

A

D

C

B

ZX1039600

–UN–10APR06

A—Adapter glass

C—Front point setting

E—Flange screw

F—Flange nut

B—Wear plate

D—Rear point setting

7. Place sensor into working position but do not latch

it. Adjust sensor assembly position so that tip of
adapter glass (A) is flush with wear plate (B) at
front point (C) and about 1 mm (0.08 in.) below
surface of wear plate (B) at rear point (D) as
shown. Use the three flange screws (E) to adjust
then secure with flange nuts (F).

IMPORTANT: To allow a proper adapter glass

self-cleaning process, make sure
that sensor position is correctly set.

NOTE: Arrow is showing the crop flow direction.

Z103757 (13DEC06)