55
8
SET MODE
7
8
■ Set mode programming
Set mode is used to change the conditions of the transceiver’s
functions: Scan type, Scan resume timer, Dual/Tri-watch, Beep
tone, LCD contrast, Automatic foghorn frequency, Radio power,
Scrambler type* and Scrambler code.*
*Appears only when the optional scrambler unit is installed.
Available functions may differ depending on how they are
set by the dealer.
q Turn power OFF.
w While pushing and holding [16•C], turn power ON to enter
Set mode.
e After the display appears, release [16•C].
r Rotate [CHANNEL] to select the desired item, push
[CHANNEL•ENTER].
t Rotate [CHANNEL] to select the desired condition of the
item.
y Push [CLR], or rotate [CHANNEL] to select “E
Ex
xi
it
t,” then
push [CHANNEL•ENTER] to exit set mode and returns to
normal operation condition.
■ Set mode items
D Scan type
The transceiver has 2 scan types: Normal scan and Priority
scan. Normal scan searches all TAG channels in the selected
channel group. Priority scan searches all TAG channels in se-
quence while monitoring Channel 16.
D
D Scan resume timer
The scan resume timer can be selected as a pause (OFF) or
timer scan (ON). When OFF is selected, the scan pauses
until the signal disappears. When ON is selected, the scan
pauses 5 sec. and resumes even if a signal has been re-
ceived on any other channel than Channel 16.
--Set Mode--
Scan Timer
ON
˘OFF
Default: OFF
--Set Mode--
Scan Type
˘Priority
Normal
Default: Priority
Rotate
--Set Mode--
˘Scan Type
Scan Timer
Dual/Tri
Beep
Contrast
Foghorn Frequency
Radio Power
Scrambler Type
Scrambler Code
Exit
• SET MODE CONSTRUCTION