Intel SDS2 User Manual
Page 51
Intel® Server Board SDS2
BIOS
Revision 1.2
Order Number: A85874-002
37
The BIOS logs the following SEL entries.
Table 22. BIOS Generated SEL Errors
Sensor Type
Sensor
Number
Sensor
Type
Code
Sensor-
Specific
Offset
Event
02h
FRB1/BIST Failure
Processor
5Fh
60h
07h
03h
FRB2/Hang in POST Failure
Memory
08h
0Ch
01h
Uncorrectable ECC
POST Memory
Resize
A0h
0Eh
–
POST Memory Resize
POST Error
06h
0Fh
–
POST Error
00h
Correctable Memory Error Logging Disabled
Event Logging
Disabled
09h
10h
01h
Event ‘Type’ Logging Disabled
00h
System Reconfigured
System Event
7Ah
12h
01h
OEM System Boot Event (Hard Reset)
04h
PCI SERR
Critical Interrupt
07h
13h
05h
PCI PERR
00h
Initiated by power up
03h
User requested PXE boot
System Boot
Initiated
A1h
1Dh
04h
Automatic boot to diagnostic
00h
No bootable media
02h
PXE Server not found
Boot Error
A2h
1Eh
03h
Invalid boot sector
00h
I2C Bus Device Address Not Acknowledged
01h
I2C Bus Device Error Detected
Sensor Failure
7Ch
F6h
02h
I2C Bus Timeout
00h
CNB2.0HE-SL function 0 errors
Chipset Specific
Critical Interrupt
F4h
F4h
02h
CIOB20 #0 errors
The Event Request Message Event Data Field Contents table below describes the various fields
in the event request message sent by the BIOS.