AC CHARACTERISTICS

PROGRAMMING (UPI-C42 AND UPI-L42)

T

A

e

25 C

g

5 C V

CC

e

6 25V

g

0 25V V

DDL

e a

5V

g

0 25V V

DDH

e

12 75V

g

0 25V

(87C42 87L42 ONLY)

Symbol

Parameter

Min

Max

Units

t

AW

Address Setup Time to RESET

u

4t

CY

t

WA

Address Hold Time after RESET

u

4t

CY

t

DW

Data in Setup Time to PROG

v

4t

CY

t

WD

Data in Hold Time after PROG

u

4t

CY

t

PW

Initial Program Pulse Width

95

105

m

s

t

TW

Test 0 Setup Time for Program Mode

4t

CY

t

WT

Test 0 Hold Time after Program Mode

4t

CY

t

DO

Test 0 to Data Out Delay

4t

CY

t

WW

RESET Pulse Width to Latch Address

4t

CY

t

r

t

f

PROG Rise and Fall Times

0 5

100

m

s

t

CY

CPU Operation Cycle Time

2 5

3 75

m

s

t

RE

RESET Setup Time before EA

u

4t

CY

t

OPW

Overprogram Pulse Width

2 85

78 75

ms

(1)

t

DE

EA High to V

DD

High

1t

CY