Intel SROMBSASMR (AXXROMBSASMR) User Manual
Page 37

Intel® Integrated RAID Module SROMBSASMR (AXXROMBSASMR) Technical Product Specification
Appendix A: Event Messages and Error Codes
Number
Type
Description
198
Information
Consistency Check Aborted Due to Ownership Loss on %s
199
Information
Background Initialization (BGI) Aborted Due to Ownership Loss on %s
200 Critical Battery/charger
problems detected; SOH Bad
201
Warning
Single-bit ECC error: ECAR=%x
202
Critical
Single-bit ECC error: ECAR=%x
203
Critical
Single-bit ECC error: ECAR=%x
204
Warning
Enclosure %s Power supply %d switched off
205
Information
Enclosure %s Power supply %d switched on
206
Warning
Enclosure %s Power supply %d cable removed
207
Information
Enclosure %s Power supply %d cable inserted
208
Information
Enclosure %s Fan %d returned to normal
209
OBSOLETE
210
Information
BBU Retention test passed
211
Critical
BBU Retention test failed!
212
OBSOLETE
213
Information
NVRAM Retention test passed
214
Critical
NVRAM Retention test failed!
215
Information
%s test completed %d passes successfully
216
Critical
%s test FAILED on %d pass. Fail data: errorOffset=%x goodData=%x badData=%x
217
Information
Self-check diagnostics completed
218
Information
Foreign Configuration Detected
219
Information
Foreign Configuration Imported
220
Information
Foreign Configuration Cleared
221
Warning
NVRAM is corrupt; reinitializing
222
Warning
NVRAM mismatch occurred
223
Warning
SAS wide port %d lost link on PHY %d
224
Information
SAS wide port %d restored link on PHY %d
225
Warning
SAS port %d, PHY %d has exceeded the allowed error rate
226
Information
Bad block reassigned on %s at %lx to %lx
227
Information
Controller Hot Plug detected
228
Warning
Enclosure %s temperature sensor %d differential detected
229
Information
Disk test cannot start. No qualifying disks found
230
Information
Time duration provided by host is not sufficient for self check
231
Information
Marked Missing for %s on array %d row %d
232
Information
Replaced Missing as %s on array %d row %d
233
Information
Enclosure %s temperature sensor %d returned to normal
234
Information
Enclosure %s Firmware download in progress
235
Warning
Enclosure %s Firmware download failed
236
Warning
%s is not a certified drive
237
Information
Dirty cache data discarded by user
238
Warning
PDs missing from configuration at boot
239
Warning
VDs missing drives and will go offline at boot: %s
240
Warning
VDs missing at boot: %s
241 Warning
Previous
configuration completely missing at boot
Revision 1.2
Intel order number E59029-003
31