Intel® Integrated RAID Module SROMBSASMR (AXXROMBSASMR) Technical Product Specification
Intel order number E59029-003
30
Number
Type
Description
154
Warning
Battery relearn timed out
155
Information
Battery relearn pending: Battery is under charge
156
Information
Battery relearn postponed
157
Information
Battery relearn will start in 4 days
158
Information
Battery relearn will start in 2 days
159
Information
Battery relearn will start in 1 day
160
Information
Battery relearn will start in 5 hours
161
Warning
Battery removed
162
Warning
Current capacity of the battery is below threshold
163
Information
Current capacity of the battery is above threshold
164
Information
Enclosure (SES) discovered on %s
165
Information
Enclosure (SAF-TE) discovered on %s
166
Critical
Enclosure %s communication lost
167
Information
Enclosure %s communication restored
168
Critical
Enclosure %s fan %d failed
169
Information
Enclosure %s fan %d inserted
170
Warning
Enclosure %s fan %d removed
171
Critical
Enclosure %s power supply %d failed
172
Information
Enclosure %s power supply %d inserted
173
Warning
Enclosure %s power supply %d removed
174
Critical
Enclosure %s EMM %d failed
175
Information
Enclosure %s EMM %d inserted
176
Critical
Enclosure %s EMM %d removed
177
Warning
Enclosure %s temperature sensor %d below warning threshold
178
Critical
Enclosure %s temperature sensor %d below error threshold
179
Warning
Enclosure %s temperature sensor %d above warning threshold
180
Critical
Enclosure %s temperature sensor %d above error threshold
181
Critical
Enclosure %s shutdown
182
Warning
Enclosure %s not supported; too many enclosures connected to port
183
Critical
Enclosure %s firmware mismatch (EMM %d)
184
Warning
Enclosure %s sensor %d bad
185
Critical
Enclosure %s phy bad for slot %d
186
Critical
Enclosure %s is unstable
187
Critical
Enclosure %s hardware error
188
Critical
Enclosure %s not responding
189
Warning
SAS/SATA mixing not supported in enclosure; %s disabled
190 Warning
Enclosure
(SES)
hot plug on %s was detected
191
Information
Clustering enabled
192
Information
Clustering disabled
193
Information
PD too small to be used for auto-rebuild on %s
194
Information
BBU enabled; changing WT virtual disks to WB
195
Warning
BBU disabled; changing WB virtual disks to WT
196
Warning
Bad block table on %s is 80% full
197
Fatal
Bad block table on %s is full; unable to log block %lx
Revision
1.2