Return codes, System error reason codes, Programmer introduced warning/error reason codes – IBM SC34-5764-01 User Manual
Page 329

Return Codes
4
Warning. Panel facility continues processing. Processing stops for other return code values.
8
Programmer error
10
Programmer error, PAN.REA contains more information to help determine the cause of the error.
See section “State Codes and Input Codes” on page 308 for more information.
12
CICS command error; the CICS EIBRESP is returned in the panel reason code. If the error is not
programmer resolvable, save and collect as much information as needed to recreate the error and
contact IBM support.
14
RFS errors; reason code contains the RFS return code
16
Internal system error; save and collect as much information as needed to recreate the error and
contact IBM support.
System Error Reason Codes
401
Panel facility ran out of storage space while processing the command
402
Internal control character identifier table and control character informational table are out of
synchronization
403
Panel object data has been corrupted. First check to see the file is correct and that it is a panel
object.
404
CICS receive buffer corrupted
405
Bad validation request
406
Storage free request failed
407
Storage get request failed
408
Attempt to get/put REXX variable failed
409
Aid is unknown
410
Dynamic match error
Programmer Introduced Warning/Error Reason Codes
101
Keyword repeated or keyword within a like category was repeated. For example, RED and BLUE;
UNDERLINE and REVERSE.
102
Keywords are incompatible. For example, PROTECT and NUMERIC
103
Missing keyword or panel name
104
The control character being defined is invalid or missing
105
Panel is too large for the screen
108
Parenthesis missing
109
Pad character invalid
110
Task has no associated terminal
111
Panel has no input fields defined during a receive
112
Panel name is invalid
115
REXX variable name (or field ID) is invalid
116
Number is specified incorrectly. Explicit length value in panel source or row col value
Panel Facility
Chapter 24. REXX/CICS Panel Facility
307