Presentation, 2 access to the circuit breakers – MGE UPS Systems 250A User Manual

Page 7

background image

34020201EN/AB

- Page 7

A-01

A-03

A-05

A-07

A-09

A-11

A-13

A-15

A-17

A-19

I 0

I 0

I 0

I 0

I 0

I 0

Q1

Q2

B-01

B-03

B-05

B-07

B-09

B-11

B-13

B-15

B-17

B-19

C-01

C-03

C-05

C-07

C-09

C-11

C-13

C-15

C-17

C-19

A-02

A-04

A-06

A-08

A-10

A-12

A-14

A-16

A-18

A-20

B-02

B-04

B-06

B-08

B-10

B-12

B-14

B-16

B-18

B-20

C-02

C-04

C-06

C-08

C-10

C-12

C-14

C-16

C-18

C-20

I

0

I

0

A-01
A-03
A-05
A-07
A-09
A-11
A-13
A-15
A-17
A-19
A-21
A-23
A-25
A-27
A-29
A-31
A-33
A-35
A-37
A-39
A-41

I 0

B-01
B-03
B-05
B-07
B-09
B-11
B-13
B-15
B-17
B-19
B-21
B-23
B-25
B-27
B-29
B-31
B-33
B-35
B-37
B-39
B-41

I 0

C-01
C-03
C-05
C-07
C-09
C-11
C-13
C-15
C-17
C-19
C-21
C-23
C-25
C-27
C-29
C-31
C-33
C-35
C-37
C-39
C-41

I 0

A-02
A-04
A-06
A-08
A-10
A-12
A-14
A-16
A-18
A-20
A-22
A-24
A-26
A-28
A-30
A-32
A-34
A-36
A-38
A-40
A-42

I 0

B-02
B-04
B-06
B-08
B-10
B-12
B-14
B-16
B-18
B-20
B-22
B-24
B-26
B-28
B-30
B-32
B-34
B-36
B-38
B-40
B-42

I 0

C-02
C-04
C-06
C-08
C-10
C-12
C-14
C-16
C-18
C-20
C-22
C-24
C-26
C-28
C-30
C-32
C-34
C-36
C-38
C-40
C-42

I 0

Q1

Q2

I

0

I

0

1. Presentation

1.2 Access to the circuit breakers

Version with 126 circuit breakers (doors open)

Version with 60 circuit breakers (doors open)

2

6

7

8

4

5

F1 disconnector-fuse for protection of the
control electronics

Upstream general protection circuit breaker
(only in modules with an isolation
transformer)

General protection circuit breaker for the 126
output circuits

2 x 21 circuit breakers for phase A (A-1 to A-
41 and A-2 to A-42)

2 x 21 circuit breakers for phase B (B-1 to B-
41 and B-2 to B-42)

2 x 21 circuit breakers for phase C (C-1 to
C-41 and C-2 to C-42)

4

5

Upstream general protection circuit breaker
(only in modules with an isolation
transformer)

General protection circuit breaker for the 60
output circuits

F2 disconnector-fuse for protection of the
voltage measurement inputs

3

F1 disconnector-fuse for protection of the
control electronics

2 x 10 circuit breakers with earth-leakage
protection for phase A (A-1 to A-19 and A-2
to A-20)
2 x 10 circuit breakers with earth-leakage
protection for phase B (B-1 to B-19 and B-2
to B-20)
2 x 10 circuit breakers with earth-leakage
protection for phase C (C-1 to C-19 and C-2
to C-20)

F2 disconnector-fuse for protection of the
voltage measurement inputs

9

Eight connection cover panels

2

6

7

8

3

9

Eight connection cover panels