Warning – Monessen Hearth BWBC500MHB User Manual

Page 23

background image

61D0087

23

Fan

Motor

1

Fan

Motor

2

On/Off

Rocker Switch

(SPST)

Cord Set

120V, 60Hz

Fireplace

Receptacle Box

Ground

Field Wire to
60Hz, 120 VAC, 15AMP
Electrical Circuit

12"max.

A

B

This fireplace is equipped with a fan assembly to help circulate heat pro-

duced by the fireplace. The energy used by the fan assembly will be less

than a 30 watt light bulb.
The fan assembly has been factory-wired to the fireplace receptacle box

located on the right side of the fireplace. Connect wiring from the fireplace

receptacle box (field-wired) to a 60 Hz, 120 vac, 15 amp electrical circuit.

Field-wiring must comply with local codes or, in the absence of local

codes, with the latest edition of National Electrical Code ANSI/NFPA 70.

See Figure 26.

Always check and make
sure power is off before
attempting to install or
service any electrical wiring
or components.

W

ARNING

Figure 26 - Wiring Diagram

Figure 25 - Locating Mantel

LOCATING MANTEL

Maximum depth of mantel is 12"
A = 6½" - Minimum from top of fireplace opening to bottom

of any combustible trim material sticking out no

more than 1½" beyond face of fireplace

B = 12" - Minimum from top of fireplace opening to bottom

of combustible trim material sticking out more than

1½" from top of fireplace opening

Top of

Fireplace

Opening

Combustible

Mantel

Non-

Combustible

Surround Trim

FAN ASSEMBLY

TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES

Combustible

Wall Board