beautypg.com

Chiimney installation, Caution – Monessen Hearth BWBC500MHB User Manual

Page 20

background image

20

61D0087

CHIIMNEY INSTALLATION

1. Extend the regular chimney sections until the top of the chimney is

4" below the total flue height desired.

2. Remove the shingles from around the chimney so that the flashing

may be installed and sealed.

For metal roofs:

Install flashing on top of roof covering. Nail

flashing down with at least eight (8) nails.

For standard roofing shingles:

Remove the shingles from

around the chimney so that the flashing may be installed. Install the

upper part of the flashing under the shingles.

3. Set the flashing on the roof. Scribe a line around the flashing. Cut

1

/

4

" below the scribed line. This should increase the diameter of the

flashing outlet enough to allow the flashing to be placed over the

chimney. See Figure 19.

4. Seal crack between the top of the flashing and the chimney with

mastic. Leave some excess mastic at this area to be used by Step 6

below.

Use pliers and wear gloves when
handling the storm collar The edge of
the storm collar is sharp. If you are not
careful, you could cut your hands.

CAUTION

CHIMNEY CAP INSTALLATION

(CONTINUED)

Figure 19 - Cutting Off Top of the

Flashing

Top of

Flashing

Figure 20 - Installing Storm Collar

and Chimney Cap

Model SC

Chimney Cap

Apply Mastic
Here

Storm Collar

Flashing

7. Place chimney cap into matching parts of the last chimney section. Push chimney cap down until the brackets on the

bottom of the chimney cap sits on the chimney pipe. Punch or drill

1

/

8

" diameter holes in the inlet air duct (chimney

pipe) where specified on the brackets. Fasten chimney pipe down with the No. 8 screws provided. See Figure 20.

Note: Do not penetrate the inner stainless steel pipe while installing the screws.

8. Check all the parts of the fireplace, chimney and chimney termination cap. Make sure none have been damaged or bent

during installation. Check to see that all parts have been properly installed.

Note: The metal used for chimney cap has a rust-protective coating but the cut edges of the parts are not

protected. Detergent-wash and paint exposed parts of chimney cap with galvanized primer paint.
This will prevent rusting and rust staining of nearby structures.

5. Place the storm collar around the chimney and put collar

together like a belt in belt loops. With the loops facing

up, slide the end of collar under the two loops on the

other end. Overlap the ends of the collar until it is tight

against the chimney. Bend the free end of the collar back

over the loops to hold the storm collar securely together.

Trim off the excess ends of the storm collar.

6. Slide storm collar down snugly against the flashing until

the excess mastic left in step six is forced up into crack

between the storm collar and chimney. This will make the

joint between the flashing and the chimney watertight.

See Figure 20.

Be careful to avoid electrical shock
hazard when contacting wires to
metal chimney components.

CAUTION

Base of Flashing

under Shingles

Standard Roofing

Shingles

This manual is related to the following products: