OUTSIDE COMBUSTION AIR

Fireplaces in
manufactured homes
must be supplied with
outside combustion air.

W

ARNING

These fireplaces are provided with model AK6A combustion air kit (for floor

installation only) to supply outside combustion air to the fireplace.
If outside wall installation or ceiling/soffit installation is preferred, pur-

chase model AK6 combustion air kit from fireplace dealer. See Figure 10,

page 12.

PRECAUTION AND RECOMMENDATIONS

1. Avoid extremely long runs and numerous turns in the flex duct leading from

the fireplace to the air inlet assembly. These conditions will increase the

resistance to the free flow of air through the flex duct.

2. Locate air inlet assembly where it will not be blocked or restricted in

any manner.

3. Never mount the combustion air inlet assembly in a garage or storage area where combustible fumes such as gasoline

might be drawn into the fireplace. Do not take combustion air from any area where combustible liquids or gases are

stored.

4. Carefully cut holes for the installation of the combustion air kit. You must maintain the structural integrity of

the home.

Maintain the structural
integrity of the
manufactured home
floor, wall, and ceiling/
roof.

CAUTION

Figure 21 - Attaching Outside Air Starting Collar and

Insulation Ring to Left Side of Fireplace

Starting

Collar

Sheet

Meal

Screws

Left Side of Fireplace

Shorter End of Air

Starting Collar

INSTALLATION OF
AK6A COMBUSTION AIR KIT

1. Remove the cover plate from the combustion air

inlet on left side of the fireplace.

2. Place the starting collar into the hole on the side

of the fireplace. Fasten collar in place with four

(4) sheet metal screws as specified by Figure

21.

3. Cut a 6½" diameter hole in floor leading into a

ventilated crawl space and install the air inlet

assembly. See Figure 22.

Locate the air inlet assembly
where it will not be blocked or
restricted in any manner. The
air inlet assembly must not
terminate in an attic space.

W

ARNING

4. Use duct straps to secure flex duct to starting

collar and inlet air assembly. See Figure 22.

Note: If it is necessary to splice the flex duct,

use Model 603 duct connector and
Model FP-6-U combustion air duct.

Figure 22 - Securing Flex Duct to Starting Collar and

Inlet Air Assembly with Duct Straps

Left Side of

Fireplace

Flex Duct

(6" Dia.)

Ventilated Crawl Space

Air Inlet

Assembly

Duct

Strap