11. If there are no abnormal problems shown on the engine

indicator, turn both the MAIN and GFCI circuit breakers
to their ON position (Figure 26).

CIRCUIT BREAKER

GFI RECEPTACLE

CIRCUIT BREAKER

MAIN

ON

ON

12. Observe the generator's ammeter (Figure 27) and verify

that it reads the anticipated amount of current with
respect to the load. Remember the ammeter will only
display a current reading if the load is in use.

13. The generator will run until manually stopped or an

abnormal condition occurs.

DCA-15SPX3 — GENERATOR START-UP PROCEDURE

Figure 26. Main and GFCI Circuit Breakers

Figure 27. Ammeter (Load)

A

0

40

60

75

20

5. Remove the load from the UNV terminal strip (Figure 14).

Engine Shutdown
To shutdown the generator use the following procedure:

1. Place both the MAIN and GFCI circuit breakers to the

"OFF position"

2. Turn the engine throttle lever to the left and push in to

decrease the engine speed.

3. Let the engine run 3-5 minutes with no load applied.

4. Turn the key to the left to stop the engine (Figure 28).

Figure 28. Ignition Switch (STOP)