Electrical work, Function settings, Fig. 6-9 – Mitsumi electronic MR. SLIM PLA-ABA User Manual

Page 9: Fig. 6-10, Fig. 6-8

background image

9

5) Assigning a remote controller to each unit
Each unit can be operated only by the assigned remote controller.
Make sure each pair of an indoor unit PC board and a remote controller is assigned
to the same pair No.
6) Wireless remote controller pair number setting operation (Fig. 6-8)

Press the SET button with something sharp at the end.

Start this operation from the status of remote controller display turned off.

blinks and Model No. is lighted.

Press the

min

button twice continuously.

Pair

No. “0” blinks.

Press the temp

buttons to set the pair number you want to set.

If you mistook the operation, press the ON/OFF

button and operate again

from procedure 2.

Press the SET button with something sharp at the end.

Set pair number is lighted for three seconds then turned off.

A Pair No. of wireless remote controller

Indoor PC board

0

Factory setting

1

Cut J41

2

Cut J42

3-9

Cut J41, J42

6. Electrical work

6.3. Function settings

6.3.1. Function setting on the unit (Selecting the unit functions)

1) For wired remote controller (Fig. 6-9)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.

Go to the function setting mode.

Switch OFF the remote controller.

Press the FILTER and TEST RUN buttons simultaneously and
hold them for at least 2 seconds. FUNCTION will start to blink.

Use the buttons to set the refrigerant address (3) to 00.
Press button and [--] will start to blink in the unit number (4) display.
Use the buttons to set the unit number (4) to 00.
Press the MODE button to designate the refrigerant address/unit number. [--]

will blink in the mode number (1) display momentarily.

Press the buttons to set the mode number (1) to 04.
Press the button and the current set setting number (2) will blink.

Use

the button to switch the setting number in response to the power supply

voltage to be used.

Power supply voltage

230 V

: setting number = 1

208 V

: setting number = 2

Press the MODE button and mode and the setting number (1) and (2) will

change to being on constantly and the contents of the setting can be confi rmed.

Press the FILTER and TEST RUN buttons simultaneously for at least two

seconds. The function selection screen will disappear momentarily and the air
conditioner OFF display will appear.

2) For wireless remote controller (Fig. 6-10)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.

Going to the function select mode

Press the

CHECK

button twice continuously.

(Start this operation from the status of remote controller display turned off.)

CHECK

is lighted and “00” blinks.

Press the

temp button once to set “50”. Direct the wireless remote controller

toward the receiver of the indoor unit and press the

h

button .

Setting the unit number

Press the

temp buttons and to set the unit number “00”. Direct the wire-

less remote controller toward the receiver of the indoor unit and press the

min

but-

ton .

Selecting a mode

Enter 04 to change the power voltage setting using the

temp buttons

and

. Direct the wireless remote controller toward the receiver of the indoor unit and

press the

h

button .

Current setting number:

1 = 1 beep (one second)

2 = 2 beeps (one second each)

3 = 3 beeps (one second each)

Selecting the setting number

Use the

temp buttons and to change the power voltage setting to 01 (240

V). Direct the wireless remote controller toward the sensor of the indoor unit and

press the

h

button .

To select multiple functions continuously

Repeat steps

and

to change multiple function settings continuously.

Complete function selection

Direct the wireless remote controller toward the sensor of the indoor unit and press

the

button .

Note: Whenever changes are made to the function settings after installation
or maintenance, be sure to record the changes with a mark in the “Setting”
column of the Function table.

6.3.2. Function setting on the remote controller

Refer to the indoor unit operation manual.

Fig. 6-9

CHECK

CHECK

ON/OFF

TEMP

FAN

VANE

TEST RUN

AUTO STOP

AUTO START

h

min

LOUVER

MODE

CHECK

RESET

SET

CLOCK

CHECK

Fig. 6-10

CHECK

CHECK

Mode number

Setting number

Refrigerant address

Unit number

PAR-21MAA

ON/OFF

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

Fig. 6-8

ON/OFF

TEMP

FAN

VANE

TEST RUN

AUTO STOP

AUTO START

h

min

LOUVER

MODE

CHECK

RESET

SET

CLOCK

MODEL SELECT

MODEL SELECT