7. Test run

OPERATION
INDICATOR
lamp blinking
pattern

Beep

Beep

Beep

Beep

Beep

Beep

Beep

Off

Approx. 2.5 sec.

On

Approx. 3 sec.

On

0.5 sec.

On

0.5 sec.

On

0.5 sec.

On

0.5 sec.

Off

Approx. 2.5 sec.

On

Approx. 3 sec.

On

0.5 sec.

On

0.5 sec.

· · · Repeated

Number of blinks/beeps in pattern indicates the check
code in the following table (i.e., n=5 for “U2”)

Number of blinks/beeps in pattern indicates
the check code in the following table

n

th

1

st

2

nd

3

rd

1

st

2

nd

Self-check
starts
(Start signal
received)

Beeper sounds

[Output pattern B]

OPERATION
INDICATOR
lamp blinking
pattern

Beep

Beep

Beep

Beep

Beep

Beep

Beep

Off

Approx. 2.5 sec.

On

0.5 sec.

On

0.5 sec.

On

0.5 sec.

On

0.5 sec.

Off

Approx. 2.5 sec.

On

0.5 sec.

On

0.5 sec.

· · · Repeated

Number of blinks/beeps in pattern indicates the check
code in the following table (i.e., n=5 for “P5”)

Number of blinks/beeps in pattern indicates
the check code in the following table

n

th

1

st

2

nd

3

rd

1

st

2

nd

Self-check
starts
(Start signal
received)

Beeper sounds

• Refer to the following tables for details on the check codes. (Wireless remote controller)
[Output pattern A]

[Output pattern A] Errors detected by indoor unit

Wireless remote controller

Wired remote

controller

Symptom

Remark

Beeper

sounds/OPERATION

INDICATOR lamp blinks

(Number of times)

Check code

1

P1

Intake sensor error

2

P2

Pipe (TH2) sensor error

P9

Pipe (TH5) sensor error

3

E6, E7

Indoor/outdoor unit communication error

4

P4

Drain sensor error / Float switch connector open

5

P5

Drain pump error

PA

Forced compressor error

6

P6

Freezing/Overheating protection operation

7

EE

Communication error between indoor and outdoor units

8

P8

Pipe temperature error

9

E4

Remote controller signal receiving error

10

11

12

Fb

Indoor unit control system error (memory error, etc.)

No sound

E0, E3

Remote controller transmission error

No sound

E1, E2

Remote controller control board error

No sound

– – – –

No corresponding

[Output pattern B] Errors detected by unit other than indoor unit (outdoor unit, etc.)

Wireless remote controller

Wired remote

controller

Symptom

Remark

Beeper sounds/OPERATION

INDICATOR lamp blinks

(Number of times)

Check code

1

E9

Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit)

For details, check the LED
display of the outdoor controller
board.

2

UP

Compressor overcurrent interruption

3

U3, U4

Open/short of outdoor unit thermistors

4

UF

Compressor overcurrent interruption (When compressor locked)

5

U2

Abnormal high discharging temperature/49C worked/insuffi cient refrigerant

6

U1, Ud

Abnormal high pressure (63H worked)/Overheating protection operation

7

U5

Abnormal temperature of heat sink

8

U8

Outdoor unit fan protection stop

9

U6

Compressor overcurrent interruption/Abnormal of power module

10

U7

Abnormality of super heat due to low discharge temperature

11

U9, UH

Abnormality such as overvoltage or voltage shortage and abnormal

synchronous signal to main circuit/Current sensor error

12

13

14

Others

Other errors (Refer to the technical manual for the outdoor unit.)

*1 If the beeper does not sound again after the initial two beeps to confi rm the self-check start signal was received and the OPERATION INDICATOR lamp does not come

on, there are no error records.

*2 If the beeper sounds three times continuously “beep, beep, beep (0.4 + 0.4 + 0.4 sec.)” after the initial two beeps to confi rm the self-check start signal was received, the

specifi ed refrigerant address is incorrect.

• On wireless remote controller
The continuous buzzer sounds from receiving section of indoor unit.
Blink of operation lamp
• On wired remote controller
Check code displayed in the LCD.