6. Electrical work

Function table
Select unit number 00

Mode
Power failure automatic recovery

Indoor temperature detecting

LOSSNAY connectivity

Power voltage

Settings
Not available
Available *1
Indoor unit operating average
Set by indoor unit’s remote controller
Remote controller’s internal sensor
Not Supported
Supported (indoor unit is not equipped with outdoor-air intake)
Supported (indoor unit is equipped with outdoor-air intake)
230 V
208 V

Mode no.

Setting no. Initial setting setting

01

1

2

1

02

2

3

1

03

2

3

04

1

2

Mode
Filter sign

Fan speed

No. of air outlets

Installed options (high-performance fi lter)

Up/down vane setting

Settings
100Hr
2500Hr
No fi lter sign indicator
Silent
Standard
High ceiling
4 directions
3 directions
2 directions
Not supported
Supported
Equipped with vanes (vanes angle setup

)

Equipped with vanes (vanes angle setup )
Equipped with vanes (vanes angle setup )

Mode no.

Setting no. Initial setting setting

1

07

2

3

1

08

2

3

1

09

2

3

10

1

2

1

11

2

3

Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])

*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.

6.3.3 How to set the fi xed up/down air direction (Only for wired remote

controller and PUZ-A/PUY-A•NHA application)

Explanation of word

• "Refrigerant address No." and "Unit No." are the numbers given to

each air conditioner.

• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the right.)
"Up/Down air direction" is the direction (angle) to fi x.

• Only the particular outlet can be fixed to certain direction with the

procedures below. Once fi xed, only the set outlet is fi xed every time air
conditioner is turned on. (Other outlets follow UP/DOWN air direction
setting of the remote controller.)

Horizontal airflow

Downward

Fixed setting

The airflow direction of
this outlet is fixed
in particular direction.

Remote controller setting

The airflow direction of
this outlet is controlled by
the airflow direction setting of
remote contoller.

When it is cold because of direct airflow,
the airflow direction can be fixed
horizontally to avoid direct airflow.

MITSUBISHI

ELECTRIC

label

Outlet No.4

Outlet No.2

Outlet No.3

Outlet No.1

Note: "0" indicates all outlets.

Reset

1

horizontal

2

3

4