Installing the grille, Installing the intake grille (fig. 9-10 ), Fig. 9-10 – Mitsumi electronic MR. SLIM PLA-ABA User Manual

Page 18

background image

18

(1) Press the

TEST

button for three seconds to

activate the maintenance mode.

(2) Press the TEMP.

buttons to set the refrigerant address.

MAINTENANCE

(3) Select the data you want to display.

MENU

ON/OFF

Compressor
information

COMP ON
x10 HOURS

COMP ON
x100 TIMES

COMP ON
CURRENT (A)

Cumulative
operation time

ON/OFF
number

Operation
current

Display

Display

Display

OUTDOOR UNIT
H•EXC. TEMP

OUTDOOR UNIT
OUTLET TEMP

OUTDOOR UNIT
OUTDOOR TEMP

Heat exchanger
temperature

Comp discharge
temperature

Outdoor ambient
temperature

Display

Outdoor unit
information

INDOOR UNIT
INLET TEMP

INDOOR UNIT
H•EXC. TEMP

INDOOR UNIT
FILTER USE H

Indoor room
temperature

Heat exchanger
temperature

Filter operation
time

Display

Indoor unit
information

* The filter operation time displayed is the number of hours the filter has been

used since the filter reset was performed.

(4) Press the

FILTER

button.

(5) The data is displayed in

.

(Airflow temperature display example)

Blinking

Waiting for
response

Approx.

10 sec.

147

* Repeat steps (2) to (5) to check another data.

(6) Press the

TEST

button for three seconds or press the

ON/OFF

button to

deactivate the maintenance mode.

Stable operation
Using the maintenance mode, the operation frequency can be fixed and the op-
eration can be stabilized. If the air conditioner is stopped, use the following pro-
cedure to start this operation.

COOL
STABLE MODE

HEAT
STABLE MODE

STABLE MODE
CANCEL

Stable cooling
operation

Stable heating
operation

Stable operation
cancellation

Display

Press the

MODE

button to select the operation mode.

Press the

FILTER

button.

Waiting for
stable operation

Display

Stable
operation

10-20 min.

* You can check the data using steps (3) to (5) of the maintenance mode opera-

tion procedures while waiting for the stable operation.

Display example (Comp discharge temperature 147 )

Display

PAR-21MAA

9. Installing the grille

Maintenance mode operation procedures

10. Easy maintenance function (For PUZ-A/PUY-A application only)

By using the maintenance mode, you can display many types of maintenance data
on the remote controller such as the heat exchanger temperature and compressor
current consumption for the indoor and outdoor units.
This function can be used whether the air conditioner is operating or not.
During air conditioner operation, data can be checked during either normal opera-
tion or maintenance mode stable operation.
* This function cannot be used during the test run.
* The availability of this function depends on the connecting outdoor unit. Refer to

the brochures.

9.7. Installing the intake grille (Fig. 9-10 )

Note:
When reinstalling the corner panels (each with a safety wire attached), con-
nect the other end of each safety wire to the grille using a screw (4 pcs,
4 8) as shown in the illustration.
*If the corner panels are not attached, they may fall off while the unit is operating.
• Perform the procedure that is described in “9.2. Preparing to attach the grille” in

reverse order to install the intake grille and the corner panel.

• Multiple units can be installed with grille so that the position of the logo on each

corner panel is consistent with the other units regardless of the orientation of the
intake grille. Align the logo on the panel according to the wishes of the customer
as shown in the diagram to the left. (The position of the grille can be changed.)

Refrigerant piping of the main unit

Drain piping of the main unit

Position of the corner panel when sent from the factory (logo attached).

* Installation in any position is possible.

Position of the levers on the intake grille when sent from the factory.

* Although the clips can be installed in any of four positions, the confi guration shown here is

recommended.(It is not necessary to remove the intake grille when maintenance is performed
on the electric component box of the main unit.)

Receiver (Only PLP-42BALM Panel)

Screw (4ޓ8)ޓ
Corner panel

Safety wire

Fig. 9-10

(Enlarged)