English – Marantz SR8001 User Manual
Page 32

ENGLISH
29
8.
8. Move the microphone to the second listening
position, select “START” with the
3
/
4
cursor
buttons and press the OK/ENTER button to
measure the second point. At this point, you
can cancel second point measurement and
calculate measurement results by selecting
“CALCULATE” and pressing the OK/ENTER
button.
A U T O S E T U P
S P E A K E R S C H E C K : O K
2 N D M I C P O S I T I O N ! !
S T A R T
C A L C U L A T E
E X I T
9.
Repeat steps 7 and 8 until measuring 6
points between the main listening position and
surrounding positions.
When all measurements end, the following
OSD appears on the display.
A U T O S E T U P
S P E A K E R S C H E C K : O K
C A L C U L A T E
E X I T
Select
“CALCULATE” with the
3
/
4
cursor
buttons and press the OK/ENTER button
to calculate measurement results. During
calculations, the following OSD appears on the
display.
A U T O S E T U P
_ _ _ _ _ _ _ _ _ _ _ _ _ _
N O W C A L C U L A T E ! !
E X I T
Note:
• Less than 6 positions can be measured, but it is
recommended to measure in all 6 positions in order
to obtain the best results.
• The time needed to complete calculations depends
on the number of connected speakers and measured
listening positions. The more speakers and listening
positions, the more time is needed.
[Example] Confi rmation screen for speaker size and
crossover frequency
S P E A K E R S I Z E
F R O N T L : A U T O
C E N T E R : A U T O
F R O N T R : A U T O
S U R R . R : A U T O
S U R R . B R : A U T O
S U R R . B L : A U T O
S U R R . L : A U T O
S U B W : A U T O
R E T U R N
N E X T
C R O S S O V E R F R E Q
F R O N T : A U T O
C E N T E R : A U T O
S U R R : A U T O
S U R R . B : A U T O
R E T U R N
* AUTO is displayed to indicate that the speaker
size and crossover frequency results were
automatically measured.
11.
Storing Measurement Results in Memory
Once finished confirming the measurement
results, select “RETURN” with the
3
/
4
cursor
buttons and press the OK/ENTER button to
display the CHECK RESULT screen.
C H A N N E L L E V E L
F R O N T L : 0 . 0 d B
C E N T E R : - 6 . 5 d B
F R O N T R : - 1 . 5 d B
S U R R . R : + 1 . 0 d B
S U R R . B R : + 9 . 5 d B
S U R R . B L : + 1 2 . 0 d B
S U R R . L : - 2 . 5 d B
S U B W : - 1 2 . 5 d B
R E T U R N
N E X T
C H E C K R E S U L T
S P E A K E R C O N F I G
S P E A K E R S I Z E
D I S T A N C E
C H A N N E L L E V E L
C R O S S O V E R F R E Q
S T O R E
E X I T
Place the cursor on “STORE” and press the
OK/ENTER button to store all parameters
including the equalizer parameters in memory.
If not wanting to store the calculation results in
memory, place the cursor on “EXIT” and press
the OK/ENTER button.
10.
Checking Measurement Results
When calculations for the measurement results
end, a screen appears for confirming the
calculation results.
C H E C K R E S U L T
S P E A K E R C O N F I G
S P E A K E R S I Z E
D I S T A N C E
C H A N N E L L E V E L
C R O S S O V E R F R E Q
S T O R E
E X I T
Select items to check with the
3
/
4
cursor
buttons and press the OK/ENTER button to
enter them.
Note:
To check equalizer (MultEQ) parameters, see page
39.
[Example] Confi rmation screen for speaker detection
S P E A K E R C O N F I G
C H E C K ! ! S P E A K E R
F R O N T : Y E S
C E N T E R : N O N
F R O N T R : Y E S
S U R R . R : Y E S
S U R R . B R : N O N
S U R R . B L : N O N
S U R R . L : Y E S
S U B W : Y E S
R E T U R N
N E X T
[Example] Confi rmation screen for the distance from
speakers to the listening position
D I S T A N C E
U N I T :
f t
F R O N T L : 3 0 . 0 0 f t
C E N T E R : 1 9 . 3 3 f t
F R O N T R : 2 9 . 6 6 f t
S U R R . R : 2 1 . 5 0 f t
S U R R . B R : 1 2 . 3 3 f t
S U R R . B L : 1 1 . 6 6 f t
S U R R . L : 1 6 . 3 3 f t
S U B W : 1 2 . 5 0 f t
R E T U R N N E X T
* The units can be changed by moving the cursor to
[ft] of UNIT and pressing
1
/
2
the cursor buttons.
Each time a
1
/
2
cursor button is pressed,
the units alternate between [ft] (feet) and [m]
(meters).
Note:
Pressing “EXIT” prior to pressing “STORE” erases all
measurement results and calculation results, therefore
operate the remote control unit with care.
When storing operations end, the following OSD
appears on the display.
2 . S P K R S E T U P
A U T O S E T U P
M A N U A L S E T U P
T H X A U D I O S E T U P
R E T U R N
E X I T
Note:
Do not turn the power to the SR7001 off while storing
parameters in memory. This may erase all data in the
SR7001’s memory and may damage the receiver.