Section 11 − standard pulse welding programs, For xmt 304 inverter welding power sources, 1. program 1 − steel – Miller Electric DS-64M Swingarc User Manual
Page 34: 2. program 2 − steel, 3. program 3 − steel

OM-1588 Page 30
SECTION 11 − STANDARD PULSE WELDING PROGRAMS
FOR XMT 304 INVERTER WELDING POWER SOURCES
Apk = Peak Amperage, Vpk = Peak Voltage, Abk = Background Amperage, PPS = Pulses Per
Second, PWms = Pulse Width (milliseconds). The following eight pulse welding programs are in
the memory of the wire feeder. Use this information if it is necessary to change a standard
program, or as a basis to build your own custom program. If at any time while changing a
standard program, or while building your own custom program, you want to go back to the
standard program in the wire feeder, perform a system reset according to Section 9-2.
Note
11-1. Program 1 − Steel
Wire Size/Type: .030”
Gas: Ar - CO
2
or Ar - Oxy / 40 CFH (19 L/m)
IPM / MPM
Apk
Vpk
Abk
PPS
PWms
COMMENTS
700 / 17.8
400
37.2
127
137
1.8
400 / 10.2
340
33.3
94
98
1.6
200 / 5.1
305
29.6
58
63
1.4
100 / 2.5
285
27.7
32
36
1.4
11-2. Program 2 − Steel
Wire Size/Type: .035”
Gas: Ar - CO
2
or Ar - Oxy / 40 CFH (19 L/m)
IPM / MPM
Apk
Vpk
Abk
PPS
PWms
COMMENTS
700 / 17.8
400
34.9
170
188
2.2
400 / 10.2
400
32.5
95
113
1.9
200 / 5.1
370
29.9
53
70
1.7
100 / 2.5
350
29.7
26
40
1.7
11-3. Program 3 − Steel
Wire Size/Type: .045”
Gas: Ar - CO
2
or Ar - Oxy / 40 CFH (19 L/m)
IPM / MPM
Apk
Vpk
Abk
PPS
PWms
COMMENTS
500 / 12.7
400
32.0
200
200
3.5
400 / 10.2
400
31.0
165
165
3.0
200 / 5.1
375
29.0
97
97
2.5
100 / 2.5
366
27.4
54
50
2.1