Section 3 − introduction, 1. specifications, Section 4 − installation – Miller Electric DS-64M Swingarc User Manual
Page 13: 1. installing swivel into pipe post

OM-1588 Page 9
SECTION 3 − INTRODUCTION
3-1. Specifications
Type of Input
Power
Welding Power
Source Type
Wire Feed Speed
Range
Wire Diameter
Range
Welding Circuit
Rating
Weight
24 Volts AC
Single-Phase
10 Amperes
50/60 Hertz
Constant Voltage (CV)
DC For GMAW Or
Constant Voltage (CV) /
Constant Current (CC) DC
For GMAW-P
All Need 14-Pin And
Contactor Control
Standard: 50 To 780 ipm
(1.3 To 19.8 mpm)
Optional High Speed: 92
To 1435 ipm (2.3 To 36.5
mpm)
.023 To 1/8 in (0.6
To 3.2 mm)
Max Spool Weight:
60 lb (27 kg)
100 Volts,
750 Amperes, 100%
Duty Cycle
12 ft (3.7 m):
207 lb (94 kg)
16 ft (4.9 m):
280 lb (127 kg)
12 ft (3.7 m) Boom
16 ft (4.9 m) Boom
Maximum Height With 4 ft (1.2 m) Post
17 ft (5.2 m)
21 ft (6.4 m)
Vertical Lift Of Boom
Horizontal to 60
°
Above Horizontal
Horizontal to 60
°
Above Horizontal
SECTION 4 − INSTALLATION
4-1. Installing Swivel Into Pipe Post
ST-152 382
1
Swingpak Base or CBC Cart
2
Pipe Post With Base
3
Steel Bolt
Secure as shown using as a mini-
mum 1/2 in diameter SAE grade 5
steel bolts.
4
Swivel Assembly
Insert into pipe post. Lubricate
swivel.
5
Safety Collar
Y Do not remove until
instructed to.
Tools Needed:
1
2
3
4
5
3/4 in