MicroBoards Technology LightScribe Series User Manual
Page 22
DVD Premium Pro LightScribe Series MICROBOARDS TECHNOLOGY, LLC
22
0C 02
WRITE
ERROR-RECOVERED WITH AUTO REALLOCATION
0C
03
WRITE ERROR-RECOMMEND REASSIGNMENT
0C
07
WRITE ERROR-RECOVERY NEEDED
0C
08
WRITE ERROR-RECOVERY FAILED
0C
09
WRITE ERROR-LOSS OF STREAMING
0C
0A
WRITE ERROR-PADDING BLOCKS ADDED
11
00
UNRECOVERED READ ERROR
11
06
CIRC UNRECOVERED ERROR
15
00
RANDOM POSITIONING ERROR
15
01
MECHANICAL POSITIONING ERROR
15
02
POSITIONING ERROR DETECTED BY READ OF MEDIUM
16
00
DATA SYNCHRONIZATION MARK ERROR
16
01
DATA SYNC ERROR-DATA REWRITTEN
16
02
DATA SYNC ERROR-RECOMMEND REWRITE
16
03
DATA SYNC ERROR-DATA ATUO-REALLOCATED
16
04
DATA SYNC ERROR-RECOMMEND REASSIGNMENT
17
00
RECOVERED DATA WITH NO ERROR CORRECTION APPLIED
17
01
RECOVERED DATA WITH RETRIES
17 02
RECOVERED
DATA
WITH POSITIVE HEAD OFFSET
17 03
RECOVERED
DATA
WITH NEGATIVE HEAD OFFSET
17
04
RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED
17 05
RECOVERED
DATA
USING
PREVIOUS SECTOR ID
17 06
RECOVERED
DATA
WITHOUT
ECC - DATA AUTO-REALLOCATED
17
07
RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT
17 08
RECOVERED
DATA
WITHOUT ECC - RECOMMEND REWRITE
17
09
RECOVERED DATA WITHOUT ECC - DATA REWRITTEN
18 00
RECOVERED
DATA
WITH
ERROR CORRECTION APPLIED
18
01
RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED
18 02
RECOVERED
DATA
-
DATA AUTO-REALLOCATED
18
03
RECOVERED DATA WITH CIRC
18
04
RECOVERED DATA WITH L-EC
18 05
RECOVERED
DATA
-
RECOMMEND REASSIGNMENT
18
06
RECOVERED DATA - RECOMMEND REWRITE
18
07
RECOVERED DATA WITH ECC - DATA REWRITTEN
19
00
DEFECT LIST NOT ERROR
19
01
DEFECT LIST NOT AVAILABLE
19
02
DEFECT LIST ERROR IN PRIMARY LIST
19
03
DEFECT LIST ERROR IN GROWN LIST
1A
00
PARAMETER LIST LENGTH ERROR
1B
00
SYNCHRONOUS DATA TRANSFER ERROR
1C
00
DEFECT LIST NOT FOUND
1C
01
PRIMARY DEFECT LIST NOT FOUND
1C
02
GROWN DEFECT LIST NOT FOUND
1D
00
MISCOMPARE DURING VERIFY OPERATION
20
00
INVALID COMMAND OPERATION CODE
21
00
LOGICAL BLOCK ADDRESS OUT OF RANGE
21
02
INVALID ADDRESS FOR WRITE
24
00
INVALID FIELD IN CDB
25
00
LOGICAL UNIT NOT SUPPORTED
26
00
INVALID FIELD IN PARAMETER LIST
26
01
PARAMETER NOT SUPPORTED
26
02
PARAMETER VALUE INVALID
26
03
THRESHOLD PARAMETERS NOT SUPPORTED
26
04
INVALID RELEASE OF ACTIVE PERSISTENT RESERVATION
27 00
WRITE
PROTECTED
27
01
HARDWARE WRITE PROTECTED
27
02
LOGICAL UNIT SOFTWARE WRITE PROTECTED
27
03
ASSOCIATED WRITE PROTECT
27
04
PERSISTENT WRITE PROTECT
27
05
PERSISTENT WRITE PROTECT
27
06
CONDITIONAL WRITE PROTECT
28
00
NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED