beautypg.com

Removal of parts for, Cleaning or sanitizing – Manitowoc Ice Q 800 User Manual

Page 20

background image

Maintenance

Section 4

4-4

REMOVAL OF PARTS FOR
CLEANING OR SANITIZING
1. Turn off the water supply to the ice machine at

the water service valve.

WARNING

Disconnect electric power to the ice machine at the
electric switch box before proceeding.

2. Remove the parts of the water curtain and the

components you want to clean or sanitize. See the
following pages for removal procedures for these
parts.

WARNING

Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or
Sanitizer.

1. Soak the removed part(s) in a properly mixed

solution.

Solution Type

Water

Mixed With

Cleaner

1 gal. (4 l)

16 oz (500 ml) cleaner

Sanitizer

4 gal. (15 l)

1 oz (30 ml) sanitizer

4. Use a soft-bristle brush or sponge (NOT a wire

brush) to carefully clean the parts.

CAUTION

Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use these
solutions in a manner inconsistent with their
labeling.

CAUTION

Do not immerse the water pump motor in the
cleaning or sanitizing solution.

5. Use the solution and a brush to clean the top,

sides, and bottom evaporator extrusions; the
inside of the ice machine panels; and the entire
inside of the bin.

6. Thoroughly rinse all of the parts and surfaces

with clean water.

7. Install the removed parts.

NOTE: Incomplete rinsing of the ice thickness probe
or water level probe may leave a residue. This could
cause the ice machine to malfunction. For best
results, brush or wipe the probes off while rinsing it.
Thoroughly dry the probes before installing them.

8. Turn on the water and electrical supply.