beautypg.com

Operational checks, General, Ice thickness check – Manitowoc Ice Q 800 User Manual

Page 15

background image

Section 3

Ice Machine Operation

3-3

Operational Checks

GENERAL
Your Manitowoc ice machine was factory-operated
and adjusted before shipment. Normally, a newly
installed ice machine does not require any
adjustment.

To ensure proper operation, always follow these
Operational Checks when starting the ice machine:
• for the first time

• after a prolonged out of service period

• after cleaning and sanitizing

Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.

WATER LEVEL CHECK
1. Check the water level while the ice machine is in

the freeze mode and the water pump is running.
The correct water level is 1/8”-1/2” (3-12.5 mm)
above the water pump impeller housing.

Water Level Check

2. The float valve is factory-set for the proper water

level. If adjustments are necessary:

A. Loosen the two screws on the float valve

bracket.

B. Raise or lower the float valve assembly as

necessary, then tighten the screws.

C. If further adjustment is required, carefully

bend the float arm to achieve the correct
water level.

ICE THICKNESS CHECK
After a harvest cycle, inspect the ice cubes in the ice
storage bin. The ice thickness probe is factory-set to
maintain an ice bridge of 1/8 inch (3.2mm). If an
adjustment is needed, follow the steps below.

1. Turn the ice thickness probe adjustment screw

clockwise for a thicker ice bridge, or
counterclockwise for a thinner ice bridge.

IMPORTANT

It is normal for cubes to have a slight dimple. This
is a normal characteristic associated with
Manitowoc’s unique shape.

Ice Thickness Adjustment

2. Make sure the ice thickness probe wire and

bracket do not restrict movement of the probe.

SV1208

1/8” ICE

THICKNESS

ADJUSTING

SCREW

WATER LEVEL

1/8”-1/2” ABOVE

HOUSING

SV1331

WATER PUMP

IMPELLER

HOUSING

WATER

PUMP

PUMP

OUTLET