Return To Table Of Contents

5-6. Activating The Dry Charge Battery (If Applicable)

Remove battery from unit.
1

Eye Protection − Safety

Glasses Or Face Shield

2

Rubber Gloves

3

Vent Caps

4

Sulfuric Acid Electrolyte

(1.265 Specific Gravity)

5

Well

Fill each cell with electrolyte to

bottom of well (maximum).
Y Do not overfill battery cells.
Wait ten minutes and check electro-

lyte level. If necessary, add electro-

lyte to raise to proper level. Reins-

tall vent caps.
6

Battery Charger

Y Read and follow all instruc-

tions supplied with battery

charger.

Charge battery for 12 minutes at 30

amperes or 30 minutes at 5 am-

peres. Disconnect charging cables

and install battery.

.

When electrolyte is low, add
only distilled water to cells to
maintain proper level.

3

Tools Needed:

1

2

4

6

30 A For 12 Minutes

5 A For 30 Minutes

OR

+

5

drybatt1 1/98 − 0886