4. volt-ampere curves for cc/cv models – Miller Electric Big Blue 402D User Manual
Page 24

OM-495 Page 18
4-4. Volt-Ampere Curves For CC/CV Models
203 414 / 203 415 / 203 413
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
A. Stick Mode
B. MIG Mode
C. TIG Mode
0
20
40
60
80
100
0
100
200
300
400
500
600
700
800
900
DC AMPERES
DC VOL
TS
Ranges
300−Max
185−425
125−320
85−190
55−90
0
20
40
60
80
100
0
100 200 300 400 500 600 700 800 900 1000
DC AMPERES
DC VOL
TS
MAX
MIN
0
20
40
60
80
100
0
50
100 150 200 250 300 350 400 450 500
DC AMPERES
DC VOL
TS
Ranges
60−310
40−200
30−130
20−70