Moxa Technologies IA5150 User Manual
Page 51
NPort IA5150/5250 Series User’s Manual
Web Console Configuration
5-26
Destination IP address
Setting
Factory Default
Necessity
IP address or Domain Name
(E.g., 192.168.1.1)
blank Optional
TCP port No.
4001
Required
The Pair Connection “Master” will contact the network host that has this IP address. Data will be
transmitted through the port No. (4001 by default). Note that you must configure the same TCP
port No. for the device server acting as the Pair Connection “Slave.”
Pair Connection Slave Mode
When using Pair Connection Mode, you must select Pair Connection Slave Mode for the
Operation mode of one of the NPort IA5150/5250 device servers. In effect, this NPort
IA5150/5250 will be acting as a TCP server.
TCP alive check time
Setting
Factory Default
Necessity
0 to 99 min
7 min
Required
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min: NPort IA5150/5250 closes the TCP connection automatically if there is no TCP
activity for the given time.
Local TCP port
Setting
Factory Default
Necessity
TCP port No. (e.g., 4001)
4001
Required
This Port No. must be the same port No. that you set up for the Pair Connection “Master” device
server.