NPort IA5150/5250 Series User’s Manual

Web Console Configuration

5-22

Connection control

Setting

Factory Default

Necessity

Startup/None,
Any Character/None,
Any Character/Inactivity Time,
DSR ON/DSR OFF,
DSR ON/None,
DCD ON/DCD OFF,
DCD ON/None

Startup/None Required

The meaning of each of the above settings is given in the table below. In general, both the Connect
condition and Disconnect condition are given.

Connect/Disconnect Description
Startup/None
(default)

A TCP connection will be established on startup, and will remain
active indefinitely.

Any Character/None

A TCP connection will be established when any character is received
from the serial interface, and will remain active indefinitely.

Any Character/
Inactivity Time

A TCP connection will be established when any character is received
from the serial interface, and will be disconnected when the Inactivity
time out is reached.

DSR On/DSR Off

A TCP connection will be established when a DSR “On” signal is
received, and will be disconnected when a DSR “Off” signal is
received.

DSR On/None

A TCP connection will be established when a DSR “On” signal is
received, and will remain active indefinitely.

DCD On/DCD Off

A TCP connection will be established when a DCD “On” signal is
received, and will be disconnected when a DCD “Off” signal is
received.

DCD On/None

A TCP connection will be established when a DCD “On” signal is
received, and will remain active indefinitely.