beautypg.com

Operating settings, Operating settings -11 – Moxa Technologies IA5150 User Manual

Page 36

background image

NPort IA5150/5250 Series User’s Manual

Web Console Configuration

5-11

Baud rate

Setting

Factory Default

Necessity

110 bps to 230400 bps

115200 bps

Required

Data bits

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

When the user sets Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 2

1

Required

Stop bits will be set to 1.5 when Data bits is set to 5 bits.

Parity

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required

Flow control

Setting

Factory Default

Necessity

None, RTS/CTS, DTR/DSR, Xon/Xoff

RTS/CTS

Required

FIFO

Setting

Factory Default

Necessity

Enable, Disable

Enable

Required

NPort IA5150/5250’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. To
prevent data loss during communication, disable the FIFO setting when your serial device does not
have a FIFO.

Interface

Setting

Factory Default

Necessity

RS-232
RS-422
2-wire RS-485
4-wire RS-485

RS-232 Required

Operating Settings

Click on Operating Settings, located under Main Menu, to display the operating settings for both
of NPort IA5150/5250’s serial ports.

This manual is related to the following products: