Bench test, Chapter – MRV Communications TERESCOPE TS800/155 User Manual
Page 36

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l
26
Bench Test
It is always easier and more convenient to locate a failure and solve a
problem in a lab on a bench than on a roof under bad conditions.
Accordingly, it is strongly recommended to perform a bench test with
all the modules prior to installation in order to check the equipment
compatibility and to validate the configuration.
See Unpacking Instructions in Appendix C.
1 – TS700/155, TS800/155, and TS800/155-F
Compatibility
Peripheral equipment
Check the operation of the peripheral equipment connected with cables (see
Configuration 1 below).
Interfaces
Check the specifications compatibility (type, wavelength, receiver range, output
power, data rate) between the TereScope and the peripheral equipment interfaces.
Test equipment
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link
quality. A portable one is preferable since it is more convenient for use in the field.
For example: the OC3 port plus SONET and ATM analyser manufactured by
Fluke.
A ping test or a file transfer between two workstations - connected to the
networking equipment - is useful and easy to do for testing the performance of the
whole configuration.
Setup
Data Rate DIP Switch Toggle
According to the application in use, set the switch toggles as indicated in the
following table: (In TS800/155 and TS800/155-F set the DS1 toggles)