Quick start – Metrologic Instruments MS9535 User Manual
Page 7
3
Q
UICK
S
TART
1. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the
bottom of the cradle. You will hear a ‘click’ when the connection is made.
2. Connect the plug of the power supply into the power jack on the bottom of
the cradle.
3. Connect the power supply into an AC outlet. The blue LED on the rear of the
cradle will stay on.
4. Pick up the scanner and scan the Bluetooth address code on the cradle; you
will hear 3 continuous beeps. After 4 seconds, both the blue LEDs of the
charger cradle and the scanner flashes, followed by 2 combination beeps.
This means the communication between the cradle and the scanner has
been established successfully.
*This is a configuration bar code attached on the cradle. Before the normal scanning,
you must establish a communication between the scanner and the receiver. Please go
to Page 8 for more details.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must
meet the requirements for SELV (
Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the
power source should meet applicable performance requirements for a limited power source.
Bluetooth Address Code*