Mocomtech SLM-5650 User Manual
Page 137

SLM-5650 Satellite Modem
Revision
1
Remote Control
MN/SLM5650.IOM
B–15
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Demod
type
RMD=
1 byte, value
of 0 thru 4
Command or Query.
Rx Modulation type, where:
0=BPSK
1=QPSK
2=OQPSK
3=8PSK
4=16QAM
Depending on FEC type, not all of these selections will be valid.
Example: RMD=1 (which is QPSK)
RMD=
RMD?
RMD*
RMD#
RMD?
RMD=x
(see description of
arguments)
Rx FEC Code
Rate
RCR=
1 byte, value
of 0 thru 8
Command or Query
Rx FEC Code Rate, where:
0 = 1/1 (Uncoded)
1 = 1/2
2 = 3/4
3 = 7/8
4 = 2/3
5 = 5/6
6 = 21/44
7 = 5/16
8 = 17/18
Depending on FEC type, not all of these selections will be valid.
Example: RCR=1 (which is Rate 1/2)
RCR=
RCR?
RCR*
RCR#
RCR?
RCR=x
(see description of
arguments)
Rx Data Rate
RDR=
10 bytes
Command or Query.
Rx Data rate, in kbps.
Resolution=1 bps.
Example: RDR=002047.999 (which is 2047.999 kbps)
N/A
RDR?
RDR=xxxxxx.xxx
(see description of
arguments)
Priority System = MOM (Highest priority), RFB, ITF, RFM, RFT, RMD, RCR, and RDR (Lowest Priority), indicated by shading. Any change to
a higher priority parameter can override any of the parameters of lower priority.