beautypg.com

Configuring snmp, Snmp read/write settings, Configuring snmp -14 – Moxa Technologies EDS-518A Series User Manual

Page 29: Snmp read/write settings -14

background image

EDS-518A Series User’s Manual

Featured Functions

3-14

Configuring SNMP

EDS-518A supports SNMP V1/V2c/V3. SNMP V1, and SNMP V2c use a community string
match for authentication, which means that SNMP servers access all objects with read-only or
read/write permissions using the community string public/private (default value). SNMP V3,
which requires you to select an authentication level of MD5 or SHA, is the most secure protocol.
You can also enable data encryption to enhance data security.

SNMP security modes and security levels supported by EDS-518A are shown in the following
table. Select the security mode and level that will be used to communicate between the SNMP
agent and manager.

Protocol

Version

UI Setting

Authentication

Type

Data

Encryption

Method

V1, V2c
Read
Community

Community
string

No

Use a community string match
for authentication

SNMP V1,
V2c

V1, V2c
Write/Read
Community

Community
string

No

Use a community string match
for authentication

No-Auth No

No

Use account with admin or user
to access objects

MD5 or SHA

Authentication
based on MD5
or SHA

No

Provides authentication based on
HMAC-MD5, or HMAC-SHA
algorithms. 8-character
passwords are the minimum
requirement for authentication.

SNMP V3

MD5 or SHA

Authentication
based on MD5
or SHA

Data encryption
key

Provides authentication based on
HMAC-MD5 or HMAC-SHA
algorithms, and data encryption
key. 8-character passwords and a
data encryption key are the
minimum requirements for
authentication and encryption.

These parameters are configured on the SNMP page. A more detailed explanation of each
parameter follows.

SNMP Read/Write Settings

SNMP Versions

Setting

Description

Factory Default

V1, V2c, V3, or
V1, V2c, or
V3 only

Select the SNMP protocol version used to
manage the switch.

V1, V2c

V1, V2c Read Community

Setting

Description

Factory Default

V1, V2c Read
Community

Use a community string match with a
maximum of 30 characters for
authentication. The SNMP agent accesses
all objects with read-only permissions
using the community string public.

public