Enter/Exit Program Mode
4
Laser Activation Range
Short Range Activation
When this option is selected, the IR sensor
Out of the Stand
is guaranteed to be activated when the posi-
tion of the scanning window three inches from
the object.
Short Range Activation
When this option is selected, the IR sensor
In the Stand
is guaranteed to be activated when an object is
presented three inches from the scanning
window.
**Long Range Activation
When this option is selected, the IR sensor
Out of the Stand
is guaranteed to be activated when the posi-
tion of the scanning window is eight inches
from the object.
**Long Range Activation
When this option is selected, the IR sensor
In the Stand
is guaranteed to be activated when an object is
presented eight inches from the scanning
window.
Laser Operation
** Normal Scan
This option is the default setting. When the laser is
activated by the IR sensor, the laser beam emits from the
output window and displays a constant, horizontal line
until a bar code is sensed or until the scanner timeout
elapses.
Pulsing Scan
When the laser is activated by the IR sensor, the laser
beam emits from the output window and displays a
horizontal line that pulses until a bar code is sensed or
until the scanner timeout elapses.
Custom Scan
This option is available for special applications.
Do not
scan the CUSTOM SCAN bar code unless
instructed by a Metrologic representative.