beautypg.com

Code 39 – Metrologic Instruments MS951 User Manual

Page 41

background image

*

*

C

T

E

C

T

F

M

D

1

M

D

2

M

D

3

M

D

4

R

1

0

R

1

1

R

A

5

R

A

6

Enter/Exit Program Mode

36

Enable ] C1 Transmit Coupon C128

*Disable ] C1 Transmit Coupon C128

Code 39

**Enable Code 39

When this option is enabled, the scan-
ner will scan Code 39 bar codes.

Disable Code 39

Enable Mod 43 Check Digit

When this option is enabled, the
scanner will only scan Code 39 bar
codes that have a Modulo 43 check
digit.

** Disable Mod 43 Check Digit

**Transmit Mod 43 Check Digit

When this option is selected, the
scanner will transmit to the host the
Modulo 43 check digit of Code 39.

Do Not Transmit Mod 43 Check Digit

Note:

Mod 43 check digit testing

must be enabled to suppress

check digit transmit.

Enable Full ASCII Code 39

When this option is enabled, the
scanner will scan full ASCII
Code 39 bar codes.

** Disable Full ASCII Code 39