beautypg.com

Provision of ventilation, Location of cooker, Conversion – Maytag 110 User Manual

Page 24

background image

24

INSTALLATION

Check the appliance is electrically safe and gas sound when you have fi nished.

Provision of Ventilation

This appliance is not connected to a combustion products

evacuation device. Particular attention shall be given to

the relevant requirements regarding ventilation.

The room containing the cooker should have an air

supply in accordance with BS 5440 Part 2 : 2000. All

rooms require an openable window or equivalent, while

some rooms require a permanent vent in addition to the

openable window. The cooker should not be installed

in a bedsitting room with volume less than 20m

3

. If it is

installed in a room of volume less than 5m

3

an air vent of

effective area 100cm

2

is required; if it is installed in a room

of volume between 5m

3

and 10m

3

, an air vent of effective

area 50cm

2

is required; while if the volume exceeds 11m

3

,

no air vent is required.

If there are other fuel burning appliances in the same

room, BS 5440 Part 2 : 2000 should be consulted to

determine the requisite air vent requirements.

Location of Cooker

The cooker may be installed in a kitchen/kitchen diner but

NOT in a room containing a bath or shower.

NOTE:

An appliance for use on LPG shall not be installed in

a room or internal space below ground level. e.g. in a

basement.

Conversion

All models are supplied set for use on group H natural

gas. A conversion kit for LP gas is included with the

appliance. See the instructions that are supplied with

the conversion kit. After converting the appliance please

attach the Gas Conversion sticker over the appropriate

area of the data badge, this will identify the gas type the

appliance is now set for.

This appliance is designed for domestic
cooking only. Use for any other purpose could
invalidate any warranty or liability claim.

You will need the following
equipment to complete the cooker
installation satisfactorily

STABILITY BRACKET

If the cooker is to be supplied with gas through a
fl exible hose, a stability bracket or chain must be
fi tted.

These are not supplied by with the cooker but
are available at most builders’ merchants.

GAS PRESSURE TESTER

FLEXIBLE GAS HOSE

Must be in accordance with the relevant
standards. A hose is not supplied by with
the cooker.
Hoses may be purchased at most
builders’ merchants.

MULTIMETER

(for electrical checks)

You will also need the following tools:

1. Electric drill
2. Masonry drill bit (only required if fi tting the

cooker on a stone or concrete fl oor)

3. Rawlplugs (only required if fi tting the cooker

on a stone or concrete fl oor)

4. Steel tape measure
5. Cross head screwdriver
6. Flat head screwdriver
7. Spirit level
8. Pencil
9. Adjustable spanner
10. Screws for fi tting stability bracket