INSTALLATION
Check the appliance is electrically safe and gas sound when you have fi nished.
Provision of Ventilation
This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to
the relevant requirements regarding ventilation.
The room containing the cooker should have an air
supply in accordance with BS 5440 Part 2 : 2000. All
rooms require an openable window or equivalent, while
some rooms require a permanent vent in addition to the
openable window. The cooker should not be installed
in a bedsitting room with volume less than 20m
3
. If it is
installed in a room of volume less than 5m
3
an air vent of
effective area 100cm
2
is required; if it is installed in a room
of volume between 5m
3
and 10m
3
, an air vent of effective
area 50cm
2
is required; while if the volume exceeds 11m
3
,
no air vent is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
Location of Cooker
The cooker may be installed in a kitchen/kitchen diner but
NOT in a room containing a bath or shower.
NOTE:
An appliance for use on LPG shall not be installed in
a room or internal space below ground level. e.g. in a
basement.
Conversion
All models are supplied set for use on group H natural
gas. A conversion kit for LP gas is included with the
appliance. See the instructions that are supplied with
the conversion kit. After converting the appliance please
attach the Gas Conversion sticker over the appropriate
area of the data badge, this will identify the gas type the
appliance is now set for.
This appliance is designed for domestic
cooking only. Use for any other purpose could
invalidate any warranty or liability claim.
You will need the following
equipment to complete the cooker
installation satisfactorily
STABILITY BRACKET
If the cooker is to be supplied with gas through a
fl exible hose, a stability bracket or chain must be
fi tted.
These are not supplied by with the cooker but
are available at most builders’ merchants.
GAS PRESSURE TESTER
FLEXIBLE GAS HOSE
Must be in accordance with the relevant
standards. A hose is not supplied by with
the cooker. Hoses may be purchased at most
builders’ merchants.
MULTIMETER
(for electrical checks)
You will also need the following tools:
1. Electric drill
2. Masonry drill bit (only required if fi tting the
cooker on a stone or concrete fl oor)
3. Rawlplugs (only required if fi tting the cooker
on a stone or concrete fl oor)
4. Steel tape measure
5. Cross head screwdriver
6. Flat head screwdriver
7. Spirit level
8. Pencil
9. Adjustable spanner
10. Screws for fi tting stability bracket