beautypg.com

Moxa Technologies 5400 User Manual

Page 37

background image

Web Console Configuration

Serial Parameters

Check the serial communication parameters in your Serial Device’s user’s manual. You should set up
NPort’s serial parameters with the same communication parameters used by your serial devices.

Baud rate

Setting

Factory Default

Necessity

50 bps to 230400 bps

115200 bps

Required

NPort supports baud rate setting from 50 bps to 230.4 Kbps.

Data bits

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 2

1

Required

Stop bits will be set to 1.5 when Data bits is set to 5 bits.

Parity

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required


Flow control

Setting

Factory Default

Necessity

None, RTS/CTS, DTR/DSR, Xon/Xoff

RTS/CTS

Required


FIFO

Setting

Factory Default

Necessity

Enable, Disable

Enable

Required

NPort’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. Disable the FIFO setting
when your serial device does not have a FIFO to prevent data loss during communication.

Interface

Setting

Factory Default

Necessity

NPort 5210: RS-232 only

NPort 5210: RS-232

Required

NPort 5230:

RS-232 for port 1

RS-422, 2-wire RS-485, 4-wire

RS-485 for port 2

NPort 5230:

Port 1: RS-232

Port 2: RS-485 2-wire

Required

NPort 5400 Series User’s

Manual

5-11