beautypg.com

Control board, Mr-g50j-nz 6-5 flowchart of trouble criterion – MITSUBISHI ELECTRIC Mitsubishi Home Refrigerator MR-G50J-SS-NZ User Manual

Page 19

background image

19

MR-G50J-NZ

6-5 FLOWCHART OF TROUBLE CRITERION

Excessive cooling

Refrigerator compartment/ Slide chilled compartment

[1]

No cooling, poor cooling

Set the temperatures
to “Low”.

No

Keep the food away
from the blowing part

Yes

Yes

Set the temperatures
to “High”.

No

Proceed to [5] at page
23.

No

No

Normal

No

Yes

Yes

The baffle does not operate

Yes

Repair the frosted part.

Refrigerator compartment

thermistor abnormal

Replace the refrigerator
compartment thermistor

Weak

Low

High

Chilled

Chilled

Middle

Refrigerator

Refrigerator
compartment
Slide chilled
compartment

Cooling

Strong

Control board

CN2A

CN4D

CN7S

4-pin
connector

6-pin
connector

Refrigerator compartment room light

Refrigerator compartment
thermistor

Slide chilled compartment
thermistor

Motor damper
(for refrigerator compartment/
slide compartment)

9
0
1
2

9
0
1
2

6

5

4

3

2

1

6

5

4

3

2

1

1
2
3
4

1
2
3
4

4

5 5

8

1

4

1

1

8

1

L

M

Are the temperatures of
refrigerator compart-
ment/ set to “Low”?

Only food around the
air blowing part get
frozen

Open the refrigerator
compartment door with
a magnet on the door
switch to check that
cold air blows from the
outlet.

Are the temperature of
refrigerator compart-
ment/ set to “High”?

Check the refrigerator compartment thermistor

Replace the motor damper (for refrig-
erator compartment/ slide chilled
compartment)

Motor damper is combined with

control panel assembly.

Is the motor damper (for refrigerator compartment/ slide
compartment) covered with frost?

Chilled compartment

thermistor abnormal

Check the chilled compartment thermistor

Jumper to be cut

JP1

1

;

lowers 1

;

lowers 1

;

highers

1

;

lowers

2

;

lowers

JP2

JP3

JP6

JP4

Temperature change

Freezer
compartment

Refrigerator
compartment

Slide chilled
compartment

1

;

lowers

JP5

Versa
compartment

Ice making
compartment

Slide chilled
compartment

Refrigerator

compartment

Versa
compart-
ment

Ice

making

compart-

ment

Attach a
magnet bar
here.

Jumper

Operation P.C. board

w

1

Cutting jumper wires on operation P.C. board can
change the set temperature of each compartment.
Unscrew the back of operation p.c. board and remove
decoration panel to cut the jumper wires.

Replace the slide chilled

compartment thermistor

Expose the damper (for refrigerator compartment/ slide com-
partment) so that its operation can be visibly checked and
conduct an ice-making test. Does the baffle open/close ?
(Wait 1 minute for self-check).
(See “Self check method and its operation,

1

Ice making

test operation” at page 14.)

Put refrigerator compartment thermistor into ice water (0

:

), dis-

connect the 4-pin connector, and measure resistance between

3

(white) and

4

(white).

Resistance at 0

:

:approx. 6-7k

"

.

Put chilled compartment thermistor into ice water (0

:

), dis-

connect the 6-pin connector, and measure resistance between

3

(white) and

6

(white).

Resistance at 0

:

:approx. 6-7k

"

.

OA090-1.qxp 06.7.20 9:55 AM Page 19