beautypg.com

2. diagnostics, Err com1 err trg1 err tch1 err mtr1, Err com2 err trg2 err tch2 err mtr2 – Miller Electric and DS-74DX16 User Manual

Page 33: Err com3, Left side motor control board pc101, Right side motor control board pc1, Dual board pc70

background image

OM-1500-14 Page 29

7-2. Diagnostics

803 063-A

1

LED3 On Right Side Motor

Control Board PC1

2

LED3 On Left Side Motor

Control Board PC101

3

LED4 On Dual Board PC70

.

There is a two-position DIP
switch S1 located on motor con-

trol boards PC1 and PC101.

These switches are factory-set

in the off position and must re-

main in that position for the unit to

operate correctly.

Error Indications
Error conditions are indicated by LED3 on

PC1, PC101, and LED4 on PC70. To view

LEDs, turn Off unit, remove wrapper, and turn

unit On.
The LED blinks in a 2.5 second cycle. The

number of blinks in this period indicates the

type of error.
The priority of the errors is related to the num-

ber of blinks indicating the error. The more

blinks, the more severe the error (motor error

is top priority). A higher priority error overrides

a lower one (if a motor error and a commu-

nication error existed, the light would blink four

times for the motor error).
Since blink On time and blink Off time are

equal in a four-blink cycle, the four−blink se-

quence appears as a constant blink.

1 blink = Communication Error

2 blinks = Trigger Error

3 blinks = Tach Error

4 blinks = Motor Error

The communication error occurs 2.5 sec-

onds after a loss of communication be-

tween the motor and the Front Panel board

or Dual board. The user may continue to

weld with this error.

The trigger error occurs if the user has the

trigger held for more than two minutes with-

out striking an arc (providing current over-

ride is not enabled), or if the user holds the

trigger past the postflow phase in a timed

weld. This error also occurs if the trigger is

held when the feeder is powered up. The er-

ror may be cleared by releasing the trigger.

The tach error occurs 2 seconds after the

loss of tachometer feedback. The user may

continue to weld with this error. The motor

speed is regulated through the monitoring of

voltage and current.

The motor error indicates that the motor

has been drawing too much current for too

long.

ERR

COM1

ERR

TRG1

ERR

TCH1

ERR

MTR1

.

Note: The error messages
are shown on the upper

and lower displays to indi-

cate specific errors. Ex-

planations are in the text

below:

Indicates a com-

munication error.

Indicates a trigger

error.

Indicates a

tachometer error.

Indicates a motor

error.

Left Side Motor Control Board PC101

ERR

COM2

ERR

TRG2

ERR

TCH2

ERR

MTR2

Indicates a com-

munication error.

Indicates a trigger

error.

Indicates a

tachometer error.

Indicates a motor

error.

Right Side Motor Control Board PC1

ERR

COM3

Indicates a

communication

error.

Dual Board PC70

2

1

3

This manual is related to the following products: