13. power source selection menu – Miller Electric and DS-74DX16 User Manual
Page 23
OM-1500-14 Page 19
4-13. Power Source Selection Menu
.
When the feeder is turned on,
the Power Source Selection
Menu allows the operator to se-
lect a default power source.
Selecting a default power
source, automatically sets the
correct Vmin and Vmax set-
tings for adjusting the output
voltage of the power source.
First Time Feeder Is Turned On
The feeder automatically goes into
the Power Source Selection Menu.
The feeder displays “dELT” on the
Upper Display and “452” on the
Lower Display, meaning that a Del-
taweld 452 is the default power
source, and has a voltage range of
10V as Vmin and 38V as Vmax.
At power up, the operator has three
seconds to select a default power
source from the list shown on the
display. Operator may scroll
through the list of power sources by
using the Adjust control. After se-
lecting a power source the operator
has three seconds to change to a
different power source or begin
welding. After making a power
source selection, the operator may
press the Program Button to avoid
having to wait the three seconds.
When turning off the feeder, the de-
fault power source will be retained.
If voltage settings have already
been set with the Vmin and Vmax in
the Auxiliary Menu, selecting a de-
fault power source with the Power
Source Selection Menu overrides
the Vmin and Vmax voltage set-
tings.
Next Time Feeder Is Turned On
The feeder will display the last se-
lected default power source. The
operator has three seconds to se-
lect another power source, or press
the Program Button to exit the Pow-
er Source Selection Menu.
Disabling The Power Source
Selection Menu
Once the default power source has
been selected the Power Source
Selection Menu may be disabled
using the Auxiliary Menus. See
Section 5-12.
1
Upper Display
2
Lower Display
Program
Start
Crater
Pre/Postflow
Trigger Hold
Adjust
Volts
Time (sec)
Wire Speed
Amps
Sequence
Setup
Dual Schedule
2
1
Non-CE Model Shown
* * Power Source
Upper Display
Lower Display
Deltaweld 452
dELT
452
Vmin =10
Vmax =38
Deltaweld 302
dELT
302
Vmin =10
Vmax =32
Deltaweld 652
dELT
652
Vmin =10
Vmax =44
Dimension 302
dIM
302
Vmin =10
Vmax =32
Dimension 452
dIM
452
Vmin =10
Vmax =38
Dimension 652
dIM
652
Vmin =10
Vmax =65
Dimension 1000
dIM
1000
Vmin =10
Vmax =60
XMT 304
XMT
304
Vmin =10
Vmax =35
XMT 456
XMT
456
Vmin =10
Vmax =38
Invision 354MP
I354
MP
Vmin =10
Vmax =35
Invision 456MP
I456
MP
Vmin =10
Vmax =38
Invision 456P
I456
P
Vmin =10
Vmax =38
PHOENIX 456
PHX
456
Vmin =10
Vmax =38
SUMMIT ARC 1000
SUM
1000
Vmin =25
Vmax =44
Voltage Range
** For any power sources not listed, pick a matching voltage range, or see Sec 4-12 to
set Vmin and Vmax.