4-13. Power Source Selection Menu

.

When the feeder is turned on,
the Power Source Selection

Menu allows the operator to se-

lect a default power source.

Selecting a default power

source, automatically sets the

correct Vmin and Vmax set-

tings for adjusting the output

voltage of the power source.

First Time Feeder Is Turned On
The feeder automatically goes into

the Power Source Selection Menu.

The feeder displays “dELT” on the

Upper Display and “452” on the

Lower Display, meaning that a Del-

taweld 452 is the default power

source, and has a voltage range of

10V as Vmin and 38V as Vmax.
At power up, the operator has three

seconds to select a default power

source from the list shown on the

display. Operator may scroll

through the list of power sources by

using the Adjust control. After se-

lecting a power source the operator

has three seconds to change to a

different power source or begin

welding. After making a power

source selection, the operator may

press the Program Button to avoid

having to wait the three seconds.

When turning off the feeder, the de-

fault power source will be retained.
If voltage settings have already

been set with the Vmin and Vmax in

the Auxiliary Menu, selecting a de-

fault power source with the Power

Source Selection Menu overrides

the Vmin and Vmax voltage set-

tings.
Next Time Feeder Is Turned On
The feeder will display the last se-

lected default power source. The

operator has three seconds to se-

lect another power source, or press

the Program Button to exit the Pow-

er Source Selection Menu.
Disabling The Power Source

Selection Menu
Once the default power source has

been selected the Power Source

Selection Menu may be disabled

using the Auxiliary Menus. See

Section 5-12.

1

Upper Display

2

Lower Display

Program

Start
Crater
Pre/Postflow

Trigger Hold

Adjust

Volts

Time (sec)

Wire Speed

Amps

Sequence

Setup

Dual Schedule

2

1

Non-CE Model Shown

* * Power Source

Upper Display

Lower Display

Deltaweld 452

dELT

452

Vmin =10

Vmax =38

Deltaweld 302

dELT

302

Vmin =10

Vmax =32

Deltaweld 652

dELT

652

Vmin =10

Vmax =44

Dimension 302

dIM

302

Vmin =10

Vmax =32

Dimension 452

dIM

452

Vmin =10

Vmax =38

Dimension 652

dIM

652

Vmin =10

Vmax =65

Dimension 1000

dIM

1000

Vmin =10

Vmax =60

XMT 304

XMT

304

Vmin =10

Vmax =35

XMT 456

XMT

456

Vmin =10

Vmax =38

Invision 354MP

I354

MP

Vmin =10

Vmax =35

Invision 456MP

I456

MP

Vmin =10

Vmax =38

Invision 456P

I456

P

Vmin =10

Vmax =38

PHOENIX 456

PHX

456

Vmin =10

Vmax =38

SUMMIT ARC 1000

SUM

1000

Vmin =25

Vmax =44

Voltage Range

** For any power sources not listed, pick a matching voltage range, or see Sec 4-12 to
set Vmin and Vmax.