Section 3 − introduction, 1. specifications, Section 4 − installation – Miller Electric and DS-74DX16 User Manual
Page 15: 1. installing swivel into pipe post
OM-1500-14 Page 11
SECTION 3 − INTRODUCTION
3-1. Specifications
Type of Input
Power
Welding Power
Source Type
Wire Feed Speed
Range
Wire Diameter
Range
Welding Circuit
Rating
Weight
24 Volts AC
Single-Phase
10 Amperes
50/60 Hertz
Constant Voltage (CV)
DC With 14-Pin And
Contactor Control
Standard: 50 To 780 ipm
(1.3 To 19.8 mpm)
Optional High Speed: 92
To 1435 ipm
(2.3 To 36.5 mpm)
.023 To 1/8 in (0.6
To 3.2 mm)
Max Spool Weight:
60 lb (27 kg)
100 Volts,
750 Amperes, 100%
Duty Cycle
12 ft (3.7 m):
207 lb (94 kg)
16 ft (4.9 m):
280 lb (127 kg)
12 ft (3.7 m) Boom (DS-12)
16 ft (4.9 m) Boom (DS-16)
Maximum Height With 4 ft (1.2 m) Post
17 ft (5.2 m)
21 ft (6.4 m)
Vertical Lift Of Boom
Horizontal to 60
°
Above Horizontal
Horizontal to 60
°
Above Horizontal
SECTION 4 − INSTALLATION
4-1. Installing Swivel Into Pipe Post
152 268-B
!
Do not remove Safety Collar
until instructed to.
1
Swingpak Base or CBC Cart
2
Pipe Post With Base
3
Steel Bolt
Secure as shown using as a mini-
mum 1/2 in diameter SAE grade 5
steel bolts.
4
Swivel Assembly
Insert into pipe post. Lubricate
swivel.
5
Safety Collar
Tools Needed:
3/4 in
1
2
3
4
5