OPERATION

GENERAL INFORMATION

This generator is not large enough to power
your entire home. Do not connect generator
to any existing electrical circuits. Plug items
directly into generator receptacles. Do not
exceed amperage rating of receptacles. Only
use grounded cords.

Figure 15 - Receptacle Locations

(MGH10000C)

120V, 15-Amp

GFCI Duplex

120/240V, 30-Amp Twist-Lock

120V, 30-Amp

Twist-Lock

120/240V, 50-Amp

Continued

Note: We supply the engine owner’s manual

with generator. Refer to that manual for ques-
tions concerning engine operation.

USING RECEPTACLE

Note: Do not exceed amperage rating of

receptacles. Exceeding rating will trip re-
ceptacle circuit breaker.
Use receptacles properly. Improper use could
damage generator. Use only grounded exten-
sion cords. Power only grounded or double-
insulated items. Do not overload receptacles.
The generators have the following receptacles
(see Figure 16):
• 120V, 15-amp GFCI duplex receptacle
• 120V, 20-amp duplex receptacle
• 120V, 30-amp twist-lock receptacle
• 120/240V, 20-amp twist-lock receptacle

(MGH8500AIE only)

• 120/240V, 30-amp twist-lock receptacle
• 1 2 0 / 2 4 0 V, 5 0 - a m p r e c e p t a c l e

(MGH10000C only)

DANGER: Never connect gen-

erator to any existing electrical

circuits. The generator output will

back-feed into the utility power

line. This may electrocute a power

company line repair person. Also,

if generator is powering electrical

circuits, the chance of an electri-

cal fire exists.

DANGER: Use only in well-

vented areas. Make sure area

has plenty of free-moving, fresh,

outside air. Never run generator

in an enclosed or confined area.

Never run generator inside oc-

cupied building. Engine exhaust

contains poisonous carbon

monoxide gas. Overexposure will

cause loss of consciousness and

will lead to death.

120V, 20-Amp

Duplex

120/2

40V

TWIS

TLOC

K

120/2

40V

TWIS

TLOC

K

120V

TWIS

TLOC

K

120V

GFCI

120V

HOU

R ME

TER

AUTO

-IDLE

RESE

T

RESE

T

RESE

T

RESE

T

OFF

ON

RE

SE

T

TE

ST

EN

M

00000005

HOURS 1/10

Figure 14 - Receptacle Locations

(MGH8500AIE)

120V, 15-Amp GFCI Duplex

120/240V, 20 Amp Twist-Lock

120V, 30-Amp Twist-Lock

120V, 20-Amp Duplex

120/240V, 30 Amp

Twist-Lock