beautypg.com

Maintenance – Multiquip MQ Power 3-Position Switch/Paralleling 1400 Amp Studio Generator SG1400C3 User Manual

Page 40

background image

page 40 — Sg1400C3 STudio generaTor • operaTion manual — rev. #0 (10/05/11)

Fuel TanK inSpeCTion

In addition to cleaning the fuel tank, the following

components should be inspected for wear:

„

rubber Suspension — look for signs of wear or

deformity due to contact with oil. Replace the rubber

suspension if necessary.

„

Fuel Hoses — inspect nylon and rubber hoses for signs

of wear, deterioration, and hardening.

„

Fuel Tank lining — inspect the fuel tank lining for signs

of excessive amounts of oil and other foreign matter.

replacing Fuel Filter

„

Replace the fuel filter cartridge with a new one every

500 hours.

„

Loosen the drain plug at the lower top of the fuel filter.

Drain the fuel in the fuel body together with the mixed

water.

do noT spill the fuel during disassembly.

„

Vent any air.

air removal

If air enters the fuel injection system of a diesel engine,

starting becomes impossible. After running out of fuel, or

after disassembling the fuel system, bleed the system.

Refer to the Cummins engine manual for details.

CHeCK oil level

Check the crankcase oil level prior to each use, or when

the fuel tank is filled. Insufficient oil may cause severe

damage to the engine. The oil level must be between the

two notches on the dipstick.

replacing oil Filter

1. Remove the old oil filter.
2. Apply a film of oil to the gasket on the new oil filter.
3. Install the new oil filter.
4. After the oil filter has been replaced, the engine oil will

drop slightly. Run the engine for a while and check for

leaks before adding more oil if needed. Clean excessive

oil from engine.

MaintEnanCE

FluSHing ouT radiaTor and replaCing

CoolanT

1. Remove radiator cap. Remove coolant drain plug

located on side of generator. Place coolant drain lever

in the open position to drain coolant.

2. Flush the radiator by running clean tap water through

radiator until signs of rust and dirt are removed. Do

not clean radiator core with any objects, such as a

screwdriver.

3. Check hoses for softening and kinks. Check clamps

for signs of leakage.

4. Move lever to the closed position and reinstall coolant

drain plug.

5. Replace with coolant as recommended by the engine

manufacturer.

6. Close radiator cap tightly.

generaTor STorage

For long term storage of the generator the following is

recommended:
1. Drain the fuel tank completely. Treat with a fuel stabilizer

if necessary.

2. Completely drain the oil from the crankcase and refill,

if necessary, with fresh oil.

3. Clean the entire generator, inside and outside.
4. Disconnect the battery.
5. Make sure engine coolant is at proper level.
6. Cover the generator and store in a clean, and dry place.

Warning

Allow engine to

cool before flushing out

radiator. Flushing the radiator while hot

could cause serious burns from water or

steam.

This manual is related to the following products: