beautypg.com

Maintenance – Multiquip MQ Power 3-Position Switch/Paralleling 1400 Amp Studio Generator SG1400C3 User Manual

Page 39

background image

Sg1400C3 STudio generaTor • operaTion manual — rev. #0 (10/05/11) — page 39

If the engine is operating in very dusty or dry grass

conditions, a clogged air cleaner will result. This can lead to

a loss of power, excessive carbon buildup in the combustion

chamber and high fuel consumption. Change air cleaner

more frequently if these conditions exist.

Fuel addiTion

Add diesel fuel (the grade may vary according to season

and locations).

removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate

in the bottom of the tank. Occasionally inspect the fuel tank

for water contamination and drain the contents if necessary.
During cold weather, the more empty volume inside the

tank, the easier it is for water to condense. This can be

reduced by keeping the tank full with diesel fuel.

Cleaning inside the Fuel Tank

If necessary, drain the fuel inside the fuel tank completely.

Using a spray washer (Figure 34) wash out any deposits

or debris that have accumulated inside the fuel tank.

Figure 34. Fuel Tank Cleaning

NOTICE

The air filter should be changed more frequently in

dusty operating conditions.

MaintEnanCE

general inSpeCTion

Prior to each use, the generator should be cleaned and

inspected for deficiencies. Check for loose, missing or

damaged nuts, bolts, and other fasteners. Also check for

fuel, oil, and coolant leaks. Use Table 14 as a general

maintenance guideline. For engine maintenance, refer to

the engine maintenance manual.

air FilTer

Every 250 hours: Remove air filter element (Figure 33) and

clean the filter element with low pressure compressed air.

Air pressure must not exceed 30 psi (207 kPa). The filter

can be cleaned and reused for up to six times if properly

cleaned. Replace air filter if rips or tears are detected while

cleaning.

air Filter dust indicator

The air filter indicator (Figure 33) is attached to the air filter.

When the air filter element is clogged, air intake restriction

becomes greater and the air filter indicator signal shows

red. When indicator is red, replace filter immediately. After

changing the air filter, press the air filter indicator button

to reset.

Figure 33. Air Filter/Indicator

Air Filter

Element

Air Filter

Indicator